DRK–3D Dark Interval
Controls the time between frames when no image is being projected to the screen.
Only applies to: Models with the Mirage license applied
Commands
Command
Description
DRK <value>
Configures how much time (in microseconds) the DMDs stay off
between frames. (Saved value)
Enabled when the selected signal is a 3D signal and 3D mode is
enabled.
Examples
Set the dark time interval to 2300µs:
(DRK 2300)
DTL–Sharpness
Adjusts the sharpness of scaled video to alter the amount of visible detail.
This command does not affect unscaled video.
Commands
Command
Description
DTL <value>
Adjusts the sharpness of scaled video to
alter the amount of visible detail. This
command is only available if video
electronics are on. (Saved value)
Examples
Apply a moderate amount of filtering to the image:
(DTL 50)
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Serial API commands
Values
250µs to 3000µs
690µs (Default)
Values
0 to 49 = Softens the image
50 = Applies a moderate amount of filtering
to the image (Default)
51 to 100 = Sharpens the image