Christie TruLife+ Technical Reference

Status system
Hide thumbs Also See for TruLife+:

Advertisement

Quick Links

Technical Reference
020-103327-03
Christie TruLife+
Status System

Advertisement

Table of Contents
loading

Summary of Contents for Christie TruLife+

  • Page 1 Technical Reference 020-103327-03 Christie TruLife+ Status System...
  • Page 2 Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
  • Page 3: Table Of Contents

    Christie TruLife+ status system........
  • Page 4: Christie Trulife+ Status System

    This guide applies to the following models. • Griffyn 4K32-RGB Product documentation For installation, setup, and user information, see the product documentation available on the Christie website. Read all instructions before using or servicing this product. 1. Access the documentation from the Christie website: •...
  • Page 5: Configuration Group (Sst+Conf?)

    Christie TruLife+ status system Configuration Group (SST+CONF?) The Configuration group provides values and fault conditions for configuration-related items in Christie TruLife+. Status State Value Description Projector Model <projector model> Displays the model for the Christie TruLife + projector. Unknown Cannot retrieve the model information.
  • Page 6 Communication Fault The device failed to respond or provided a bad response to a command while the light source is on. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 7 A fatal power supply error occurred. See the logs for more information. AC Input Failure The power supply suffered from an input failure. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 8 Formatter-Red The formatter is in standby without any cached errors or warnings. Formatter-Green Formatter-Blue Properly detected and initialized the formatter. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 9 The diffuser is spinning at less than 100 RPM. 144 Photon Module The module is working properly. Unknown Displayed if the housekeeping board is not yet initialized. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 10: Signal Group (Sst+Sign?)

    The device failed to respond or provided a bad response to a command while the projector is in Standby mode. Signal Group (SST+SIGN?) The Signal group provides values and fault conditions relating to the video signal status for Christie TruLife+. Status State...
  • Page 11 <input type> <active window> Where @ <v-sync rate> (<status>) 5016 VOM Port <input type> : { HDMI, DP, SDI, VOM } Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 12 Receiving video Christie Link is receiving video (LED is green). Incoming video ignored Video ignored (LED is red). Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 13: Illuminator Group (Sst+Lght?)

    Lasers are off. Power.Warm Up Lasers are in the process of turning on. Power.Cool Down Lasers are off and cooling down. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 14 116 Laser LOS Humidity <RH value> % Displays the humidity in the LOS. <RH value> % Humidity exceeds the warning threshold. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 15 A housekeeping board (HKB) hardware version mismatch exists. 127 Laser CSB HW Version <type>.<version>.<mod> Color sensor board (CSB) hardware version is OK. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 16 Voltage exceeds the warning threshold. Laser Red Driver X Temp <value>°C Displays the current temperature of the sensor. <value>°C Temperature exceeds the warning threshold. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 17 Laser Tec X Driver Amps <value> A Displays the current amperage of the sensor. <value> A Amperage exceeds the warning threshold. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 18: Version Group (Sst+Vers?)

    The formatter has never been turned on or initialized. Power Supply HW Version <model>.<version>.<name> The version information of the 48V power supply. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 19 Cannot retrieve the hardware version as the board is not ready. BIOS SW Version <version> Displays the BIOS software version. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 20: Temperature Group (Sst+Temp?)

    <value> °C - Too Cold Temperature is below the (shutdown) error threshold. Cooling Group (SST+COOL?) The Cooling Group provides values and fault conditions related to cooling and fans for Christie TruLife Status State Value Description Formatter-Green (Fan 4) <tach>...
  • Page 21 Liquid cooling is off. Unknown The liquid cooling status is unavailable. <value> RPM - Low RPM Pump is running under expected RPM. Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 22: Serial Group (Sst+Seri?)

    RPM. 123 Fan Speed Profile <mode> Reflects the fan mode: Standard or Quiet. Serial Group (SST+SERI?) The Serial Group provides values and fault conditions related to hardware serial numbers for Christie TruLife+. Status State Value Description Main Control Board S/N <serial number>...
  • Page 23 State Value Description Missing S/N Cannot retrieve the value because the serial number was not programmed into the board correctly Christie TruLife+ Technical Reference–Status System 020-103327-03 Rev. 1 (04-2021) Copyright © 2021 Christie Digital Systems USA, Inc. All rights reserved.
  • Page 24 Corporate offi ces Worldwide offi ces Christie Digital Systems USA, Inc. Africa Columbia Mexico United States (Arizona) ph: 714 236 8610 ph: +27 (0)11 510 0094 ph: +57 (318) 447 3179 ph: +52 55 4744 1790 ph: 602 943 5700...

Table of Contents