Commands
Command
Description
TMC+MODE ?
Returns the fan control profile in use. (Read-
only)
TMC+MODE <value> Selects the fan control profile. (Saved value)
Examples
Return the fan control profile in use:
(TMC+MODE ?)
Result:
(TMC+MODE! "Standard")
Achieve the lowest noise possible:
(TMC+MODE 1)
TMD–Time and Date
Sets the date and time in the real-time clock.
Commands
Command
Description
TMD+DATE <date>
Sets the date for the clock.
TMD+TIME <time>
Sets the time for the clock.
Examples
Set the date to January 17th, 2020:
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Values
• 0 = Standard—The projector attempts
to achieve a balance between low noise
and brightness performance by
adjusting fan speed with regards to
ambient temperature and requested
brightness. (Default)
• 1 = Quiet—The projector achieves the
lowest noise at the possible expense of
brightness performance.
• 2 = Performance (Only applies to
Christie M RGB Series, Griffyn 4K35-
RGB, and Griffyn 4K50-RGB)—The
projector brightness is not restricted by
fan speed.
Values
<date> = String in the following format:
YYYY/MM/DD
<time> = String in the following format:
hh:mm:ss