Command
Description
RAL+PRTA <value>
Sets the access level for the RS232 port.
(Saved value)
Examples
Set port to Login Required:
(RAL+PRTA 1)
SDI–SDI Payload Overrride
Overrides the SMPTE 352M payload for HBMIC-SDI inputs.
This setting applies to all HBMIC-SDI inputs in the system (such as, not per input).
Commands
Command
Description
SDI <value>
Changes the HBMIC-SDI payload override
setting. This command is only available if
the video electronics are on. (Saved value)
SDI+PAYL "<custom
Defines the customized SMPTE 352M
string>"
payload as a 4-byte hex string when the
SDI command is set to custom. For more
details, contact Christie Technical Support.
This command is only available if the video
electronics are on. (Saved value)
Examples
Set the SDI payload to the pre-defined 3G-A 1080p59.94 option:
(SDI 3)
Set the SDI payload to a custom entry, for example 1080p23.98.4:2:2:
(SDI 1)
(SDI+PAYL "04C20500")
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Serial API commands
Values
2 = Free Access—Executes commands at
the operator level unless a separate login is
performed (Default)
Values
0 = Auto Detect (Default)
1 = Custom
2 = 3G-A 1080p60
3 = 3G-A 1080p59.94
4 = 3G-A 1080p50
5 = 3G-A 2K60
6 = 3G-A 2K59.94
7 = 3G-A 2K50
custom string = 4-byte hex string in big-
endian order:
"<b0><b1><b2><b3>"