Examples
Return the 3D input inversion value on main video:
(TDN?)
Set 3D input inversion to inverted on main video:
(TDN 0)
TDO–3D Sync Out
Configures the 3D Sync OUT port for either an emitter or for another downstream projector.
Only applies to: Models with the Mirage license applied
Commands
Command
Description
TDO?
Returns the 3D Sync Out value on main
video. (Read-only)
TDO <0 | 1>
Configures the 3D Sync OUT port. (Saved
value)
Enabled when the selected signal is a 3D
signal and 3D mode is enabled.
Examples
Return the 3D Sync Out value on main video:
(TDO?)
Set 3D Sync Out to Off on main video:
(TDO 0)
Set 3D Sync Out to To Emitter:
(TDO 1)
Related information
TDD–3D Sync Delay (on page 58)
TDN–Invert 3D Input (on page 59)
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Serial API commands
Values
—
0 = Configures the 3D Sync OUT port to be
fed directly to a 3D emitter, including any
3D sync delay and/or sync inversion
(Default)
1 = Configures the 3D Sync OUT port to be
fed to another downstream projector,
without including any 3D sync delay or
inversion
60