Summary of Contents for Christie TruLife+ Griffyn 4K32-RGB
Page 1
User Guide 020-103315-01 Christie TruLife+...
Page 2
The warranty does not apply to any product where the serial number has been removed or obliterated. The warranty also does not apply to any product sold by a reseller to an end user outside of the country where the reseller is located unless (i) Christie has an office in the country where the end user is located or (ii) the required international warranty fee has been paid.
Griffyn 4K32-RGB • Mirage 4K32-RGB Product documentation For installation, setup, and user information, see the product documentation available on the Christie website. Read all instructions before using or servicing this product. 1. Access the documentation from the Christie website: •...
Read all safety and warning guidelines before installing or operating the projector. This projector must be operated in an environment that meets the operating range specification. Use only the attachments and/or accessories recommended by Christie. Use of others may result in the risk of fire, shock, or personal injury.
Possible hazardous optical radiation emitted from this product. (Risk group 3) • Only Christie qualified technicians who are knowledgeable about the hazards associated with laser use, high-voltage, and high temperatures generated by the product are authorized to assemble, install, and service the Christie Laser Projection System.
Page 10
Permanent show installations containing Risk Group 3 laser-illuminated projectors must meet the following conditions: • Installed by Christie or by Christie-authorized and trained installers. Refer to the Laser Illuminated Projector - Class 1 Risk Group 3 Installation training (Course code: CF-LIPI-01) on the http://www.christieuniversity.com site.
• Temporary show installations containing Risk Group 3 laser-illuminated projectors may be installed by Christie or sold or leased only to valid laser light show variance holders (laser light show manufacturers) for image projection applications. Such manufacturers may currently hold a valid variance for production of Class IIIb and IV laser light shows and/or for incorporation of the Risk Group 3 laser-illuminated projectors into their shows.
Christie Professional Services: +1-800-550-3061 or NOC@christiedigital.com Contact your dealer Record the information about your projector and keep this information with your records to assist with the servicing of your projector. If you encounter a problem with your Christie projector, contact your dealer. Purchase record...
Front IR Receives transmissions from the IR remote. Service door Provides access to the fold mirror, optical zoom/focus, and DMD convergence adjustments as well as the tools for Christie qualified technicians. Display panel Displays the projector menus and status. Keypad interface Controls the projector.
Adjusting the image Adjust the projector image. Christie recommends warming the lens before completing these procedures as focus may change as the lens warms. Selecting screen image orientation Specify the orientation to use for the image. The projector supports front projection, rear projection, front projection inverted, or rear projection inverted.
• Show All Warnings—Shows all lens warnings. • Hide Zoom Motor Warnings—Hides zoom motor warnings. Christie recommends selecting this option when using a fixed lens as all zoom operations are disabled. • Hide Detection Warnings—Hides lens detection warnings. Christie recommends selecting this option when using a third-party lens.
Signal color correction Adjust the video signal color as required. For best results, Christie recommends setting all color and gamma settings to Auto Detect. Adjusting the color space Determine how the color components are decoded for accurate color in the display.
Combine several projected images into one single, seamless image with edge blending. Adding edge blends to the projector Use Christie Twist or Mystique to create edge blends and upload them to Christie TruLife+. 1. Create an edge blend file using the Christie Twist or Mystique application.
1. Create a warp file using the Christie Twist or Mystique application. To connect Christie TruLife+ with Christie Twist or Mystique, use port 3003. Christie Twist Premium, Twist Pro, and Mystique offer advanced warping options. Refer to the Christie website (www.christiedigital.com) for product information and documentation.
3. Select Enter. Informing the source of signal preferences Configure Christie TruLife+ to automatically inform the video source of the preferred signal formats. 1. If you need a specific frame rate, from the display panel, select MENU > Configuration >...
Configuring LiteLOC ™ To ensure color and brightness are held at the required levels for your installation, Christie recommends enabling LiteLOC with your required settings for each laser configuration you create. 1. To configure LiteLOC, navigate to MENU > Configuration > Light & Output Settings.
1. Ensure the projector is running in representative ambient light. 2. Setup a spectroradiometer, such as the CR-250, on a tripod. If not using the CR-250 or better, Christie recommends placing the meter perpendicular to the screen to achieve accurate measurements.
There are 512 channels per universe. Christie TruLife+ specifies 24 channels. Christie TruLife+ has multiple methods of being controlled in addition to Art-Net. If a setting is changed through another interface, the DMX controller can re-assert control by changing the value on the appropriate DMX channel.
Four-Port SDI Working with macros Automate tasks in Christie TruLife+ with macros so the same tasks can be done on a regular basis. If the date and/or time is changed on the projector, a macro may be unexpectedly executed. Adding a Scheduled Event macro Create a Scheduled Event macro to automate a repetitive task.
An input pin can only have a maximum of two events, one for each transition type. 7. In the Serial Command field, enter the serial command(s) you want to run. For available serial commands and their syntax, refer to the Christie TruLife+ Serial Commands Guide (P/N: 020-103316-XX).
(SST+CONF?1) serial API command. Christie Technical Support will send a zipped license file to you. If you sent more than one serial number, you will receive multiple license files as the .key file is based on the serial number of the projector.
10. Repeat steps 3 to 9 for each additional projector. Exporting backup settings to an external device Save the Christie TruLife+ settings to a USB flash drive (projector) or file (web interface). 1. If using the display panel to export settings, insert a USB flash drive (properly formatted as FAT) into the USB port on Christie TruLife+.
The backup settings file is imported to the projector. Restoring projector default settings Restore the Christie TruLife+ settings back to the default values. Network configurations and calibration values are not reset. 1. From the display panel, select MENU > Admin > Backup & Restore.
Follow these procedures to help with diagnosing issues with Christie TruLife+. Viewing Christie TruLife+ information View the licenses for the software added to Christie TruLife+ and the licenses of the software used to operate Christie TruLife+. The information is read-only.
2. Scroll to the status category you want to view and select it. Running the Christie TruLife+ interrogator The interrogator captures diagnostic information Christie personnel uses to help diagnose and correct any issues. 1. If saving the interrogator file to a USB flash drive on the projector, insert a USB flash drive in the USB port on Christie TruLife+.
Diagnostic tools • If running Christie TruLife+ interrogator from the web interface, a message appears indicating the integrator file was successfully created. 4. From the web interface to download the interrogator file to the computer, select Download File. The interrogator file is downloaded to the default location on the computer.
Page 62
Corporate offi ces Worldwide offi ces Christie Digital Systems USA, Inc. Africa United Kingdom Columbia Korea (Seoul) ph: 714 236 8610 ph: +27 (0)11 510 0094 ph: +44 (0) 118 977 8000 ph: +57 (318) 447 3179 ph: +82 2 702 1601 Christie Digital Systems Canada Inc.