4.3 Description of Keys on Operation Panel

Symbol
Shuttle−typ
Key−type
e
Knob+
Knob−
Note:
The ENTER key of shuttle type operation panel is equivalent to PRG Key.
Using PRG key continuously can realize fast browse of all function codes.
26
E5−H High Performance Universal Inverter
Name
1 、
Programming key
2 、
3 、
PRG
4 、
1 、
2 、
Escape Key
3 、
ESC
4 、
1 、
Increase Key
2 、
3 、
1 、
Decrease Key
2 、
3 、
1 、
2 、
Shift Key
3 、
>>
4 、
1 、
Run Key
2 、
RUN
1 、
2 、
Stop/Reset Key
STOP/RST
3 、
Multi − function Key
See table 4−1 for the using method of multi−function key and the
meanings of MULTI indicator.
M
Forward/reverse
When running command is given via operation panel, this key is used to
Key
confirm the output direction of inverter
FWD/REV
Chapter 4 Using Instructions of Operation Panel
Enter each level of menu
Validate data change
Check function code in sequence
Confirm the Running command issuing mode with M key
Back to first level menu from second level menu; Back from first
level menu to standby status, running status, and fault status
Give up data change after modifying data.
Back to basic menu mode after pressing this key for more than 5s.
Refer to 4.4.3. When LCD cannot display all the function codes,
use this method to re−display all the function codes.
After using >> key to switch from fault display to Stop / Run
parameter display, press ESC to back to fault display status.
In first level menu, increase function code according to edit bit.
In second level menu, increase the function code data.
In stop/run status, increase the input frequency or close loop input.
In first level menu, decrease function code according to edit bit.
In second level menu, decrease the function code data.
In stop/run status, decrease the input frequency or close loop input.
In first level menu, use >> key to move edit bit of PX.YZ menu
In second level menu, use >> key to move the edit bit of data
In stop/run status, switch the panel display parameters such as
frequency, current and voltage.
In fault status, change from fault display to stop/run display.
When running command is given via operation panel, press the key
to start the inverter.
After setting the parameter auto tuning,start parameter auto tuning
for inverter startup
When running command is given via operation panel, press the key
to stop the inverter.
This key is used as a stop key when inverter only has fault alarm
but does not stop.
When the inverter has fault and has stopped, this key is used as
RESET key to clear the fault alarm.
User Manual