V&T E5-H Series User Manual page 47

High performance universal inverter
Table of Contents

Advertisement

Function
code
Function code name
number
Multi−function key
P2.01
definition
Display parameter
P2.02
selection at running
Display parameter
P2.03
selection at stopping
Running proportion
P2.04
display benckmark
Running proportion
P2.05
display coefficient
Stopping proportion
P2.06
display benckmark
Stopping proportion
P2.07
display coefficient
40
E5−H High Performance Universal Inverter
Factory
Setting range
setting
1
0 ~ 8
1CB0
0 ~ FFFF
3210
0 ~ FFFF
0
0 ~ F
0.00
0.00 ~ 655.35
0
0 ~ F
0.00
0.00 ~ 655.35
Chapter 5 List of Parameters
User Manual
Unit
Property
Function code selection
0: No function;
1: Jog function;
2: Emergent shutdown 1(Stop in
shortest time);
3: Emergent shutdown 2
(Coast−to−stop);
4: Switch of input method of running
command
(Operation panel/Terminal/Host
/
computer);
5: Function code display switching
(fast/all);
6: Function code display switching
(different from leave−factory/all);
7: Function code display switching (the
last changed 10 function codes/all);
8: Function code display switching
(P0.02 menu mode switching)
LED ones place:
0: Reference frequency (Hz);
1: Bus voltage (V);
2: AI1(V);
4: Reserved;
6: External counting;
7: Motor rotation speed (rpm);
8: Close loop reference (%);
/
9: Close loop feedback (%);
A: Reserved;
B: Running frequency (Hz);
C: Output current (A);
D: Output torque (%);
E: Output power (kW);
F: Output voltage (V);
LED tens, hundreds, thousands place:
Same with above
LED ones place:
0: Reference frequency (Hz);
1: Bus voltage (V);
2: AI1(V);
4: Reserved;
6: External counting;
7: Motor rotation speed (rpm);
8: Close loop reference (%);
/
9: Close loop feedback (%);
A: Reserved;
B: Reserved;
C: Reserved;
D: Reserved;
E: Reserved;
F: Reserved;
LED tens, hundreds, thousands place:
Same with above
/
0 ~ F
%
0.00 ~ 655.35
/
0 ~ F
%
0.00 ~ 655.35
setting
3: AI2(V);
5: Reserved;
3: AI2(V);
5: Reserved;
User

Advertisement

Table of Contents
loading

Table of Contents