V&T E5-H Series User Manual page 48

High performance universal inverter
Table of Contents

Advertisement

Function
code
Function code name
number
P3.00
Startup mode
P3.01
DC injection current
P3.02
DC injection time
P3.03
Startup frequency
Startup frequency
P3.04
retention time
P3.05
Stop mode
DC braking initial
P3.06
frequency
P3.07
DC braking current
P3.08
DC braking time
P3.09
Anti − reverse selection
Forward / reverse dead
P3.10
zone time
P3.11
Jog frequency
P3.12
Jog acceleration time
P3.13
Jog deceleration time
P4.00
V/F curve reference
P4.01
V/F frequency value F0
P4.02
V/F voltage value V0
P4.03
V/F frequency value F1
P4.04
V/F voltage value V1
P4.05
V/F frequency value F2
P4.06
V/F voltage value V2
P4.07
V/F frequency value F3
P4.08
V/F voltage value V3
P4.09
Acceleration time 1
P4.10
Deceleration time 1
P4.11
Acceleration time 2
P4.12
Deceleration time 2
P4.13
Acceleration time 3
P4.14
Deceleration time 3
Multi − section digital
P4.15
voltage reference 1
Multi − section digital
P4.16
voltage reference 2
Multi − section digital
P4.17
voltage reference 3
E5−H High Performance Universal Inverter
Factory
Setting range
setting
Group P3
0
0 ~ 2
0.0
0.0 ~ 120.0
0.00
0.00 ~ 30.00
0.0 or
0.00 ~ 60.00
0.50
0.0
0.0 ~ 3600.0
0
0 ~ 2
0.00
0.00 ~ 300.00
0.0
0.0 ~ 120.0
0.00
0.0 0~ 30.00
1
0 ~ 1
0.0
0.0 ~ 3600.0
5.00
0.10 ~ 300.00
6.0
0.1 ~ 60.0
6.0
0.1 ~ 60.0
Group P4
Multi−section Parameter
0
0 ~ 6
0.00
0.00 ~ 300.00
0.0
0.0 ~ 100.0
0.00
0.00 ~ 300.00
0.0
0.0 ~ 100.0
0.00
0.00 ~ 300.00
0.0
0.0 ~ 100.0
0.00
0.00 ~ 300.00
0.0
0.0 ~ 100.0
20.0
0.1 ~ 3600.0
20.0
0.1 ~ 3600.0
20.0
0.1 ~ 3600.0
20.0
0.1 ~ 3600.0
20.0
0.1 ~ 3600.0
20.0
0.1 ~ 3600.0
1.00
0.00 ~ 10.00
2.00
0.00 ~ 10.00
3.00
0.00 ~ 10.00
Chapter 5 List of Parameters
User Manual
Unit
Property
Start/stop Parameter
0: Normal startup;
/
×
1: Start after DC injection;
2: Catch a spinning motor
Constant torque: 0.0 ~ 120.0% inverter
%
×
rated current
s
×
0.00 ~ 30.00s
0.00 ~frequency high limit the lower of
Hz
×
P0.13 and 60.00Hz
s
×
0.0 ~ 3600.0s
0: Deceleration to stop;
/
×
1: Coast to stop;
2: Deceleration to stop+DC braking
Hz
×
0.00 ~ 300.00Hz
Constant torque: 0.0 ~ 120.0% inverter
rated current
%
×
Variable torque: 0.0 ~ 90.0% inverter
rated current
s
×
0.00~ 30.00s
0: Run reverse enabled;
/
×
1: Run reverse disabled
s
×
0.0 ~ 3600.0s
Hz
×
0.10 ~ 300.00Hz
s
×
0.1 ~ 60.0s
s
×
0.1 ~ 60.0s
0: Direct line;
1: Multi−section (P4.01 ~ P4.08);
2: Power of 1.2;
/
×
3: Power of 1.4;
4: Power of 1.6;
5: Power of 1.8;
6: Power of 2
Hz
×
F0<F1
%
×
0.0 ~ 100.0%
Hz
×
F1<F2
%
×
0.0 ~ 100.0%
Hz
×
F2<F3
%
×
0.0 ~ 100.0%
Hz
×
F3< Motor basic frequency P0.15
%
×
0.0 ~ 100.0%
s
×
0.1 ~ 3600.0s
s
×
0.1 ~ 3600.0s
s
×
0.1 ~ 3600.0s
s
×
0.1 ~ 3600.0s
s
×
0.1 ~ 3600.0s
s
×
0.1 ~ 3600.0s
V
0.00 ~ 10.00V
V
0.00 ~ 10.00V
V
0.00 ~ 10.00V
Function code selection
User
setting
41

Advertisement

Table of Contents
loading

Table of Contents