4.3 Description of Keys on Operation Panel

Symbol
Shuttle type
Key type
Knob+
Knob−
Note:
 The press down the knob of shuttle type operation panel is equivalent to PRG Key.
 Pressing PRG key continuously can realize browse of all parameters.
E5 Series High Performance Universal Inverter
Name
T.Enter each level of menu
Programming key
T.Confirm displayed data storage
PRG
3.Check parameters in sequence
4.Confirm changeover of the run command channel with M key
T.Back to first level menu from second level menu; Back from first level
T.Give up data storage after modifying data
Escape Key
3.Back to all parameters displayed mode after pressing this key for
ESC
4.After pressing >> key to switch from fault display to Stop T Run
T.In first level menu, increase parameters according to edit bit
Increase Key
T.In second level menu, increase the parameters value
3.In stopTrun status, increase the frequency reference or PID main
T.In first level menu, decrease parameters according to edit bit
Decrease Key
T.In second level menu, decrease the parameters value
3.In stopTrun status, decrease the frequency reference or PID main
T.In first level menu, press >> key to select edit bit of PX.YZ menu
T.In second level menu, press >> key to select the edit bit of data
Shift Key
3.In stopTrun status, press >> key to display parameters such as
>>
4.In fault status, change from fault display to stopTrun display
T.When running command is given via operation panel, the key is used
Run Key
RUN
T.After setting the motor data identification, press RUN key to start
T.When running command is given via operation panel, the key is used
StopTReset Key
T.This key is used as a stop key when inverter has fault alarm but not
STOPTRST
3.When the inverter has fault and stopped, this key is used as RESET
Multi−function
See table 4−T for the using method of multi−function selection M key
selection Key
function selection and the meanings of MULTI indicator
M
ForwardTReverse
When running command is given via operation panel, this key is used to
Key
change the output direction of motor
FWDTREV
Chapter 4 Operation Panel
menu to standby status, running status, and fault status from first
level menu
more than 5s. Refer to 4.4.3. When LCD cannot display all the
parameters, use this method to re−display all the parameters
parameters display, press ESC to back to fault display status
reference
reference
frequency, DC BUS voltage, current and voltage, etc.
to start the motor
motor data identification
to stop the motor
stop
key to clear the fault alarm