V&T E5-H Series User Manual page 62

High performance universal inverter
Table of Contents

Advertisement

the analog and the reference frequency is defined by group P6.
Note: When adopting the current input of 0~20mA, refer to the description of P6.01~P6.08. .
P0.06
There are 3 modes for issuing running commands for the inverter.
0: Operation panel mode: Perform the Run, Stop, Forward/reverse running of the inverter through the
RUN, STOP/RST, FWD/REV buttons of the operation panel.
1: Terminal mode: Perform the Run, Stop, Forward/reverse running of the inverter by defining the
multi−functional terminals X1~X4. Refer to the description of P5.00~P5.06 and P5.11.
2: Host computer mode: Perform the Run, Stop, Forward/reverse running of the inverter through
communication. Refer to the appendix A Modbus communication protocol.
P0.07
This parameter is used to change the rotation direction of the motor when the running command is given
through operation panel (P0.06=0).
0: Forward; 1: Reverse
Note: This function code is disabled when the running command is issued via terminal, and the running
direction is controlled by terminal command.
P0.08
P0.09
P0.10
This function can set the speed and stability in the duration from acceleration to constant speed after the
startup of the inverter, or from constant deceleration to stop.
Acceleration time 0: The time that the inverter accelerates from 0 frequency to maximum frequency.
Deceleration time 0: The time that the inverter accelerates from maximum frequency to 0 frequency.
S curve time: The time for adding curve segment to improve the smoothness of the start and ending
section during the acceleration and deceleration, P0.10. S curve time is applicable to the belt conveyer
that carries fragile materials or applications requiring smooth speed adjustment.
E5−H High Performance Universal Inverter
Running command issuing mode
Running direction command
Acceleration time 0
Deceleration time 0
S curve time
Chapter 6 Parameter Description
User Manual
0~2(0)
0~1(0)
0.1~3600.0 s(6.0s or 20.0s)
0.1~3600.0 s(6.0s or 20.0s)
0.0~3600.0 s(0.0s)
55