Appendix B Control Mode Setting Process; Setting Process For Auto−Tuning - V&T E5-H Series User Manual

High performance universal inverter
Table of Contents

Advertisement

Appendix B Control Mode Setting Process

1. Setting Process for Auto−tuning
Parameter auto−tuning under V/F control
Setting rated voltage of motor
Setting rated frequency of motor
Setting upper frequency limit of motor
Setting max frequency of motor
Motor with multi power V/F
124
E5−H High Performance Universal Inverter
START
Setting P0.01=5
P0.12
P0.15
P0.13
P0.11
Motor with multi V/F
N
N
Setting motor parameter
(P9.00 P9.04)
Setting P9.15=1
Press RUN key to perform
parameter tuning
END
Appendix B Control Mode Setting Process
User Manual
Setting P4.00=1,
Y
auto torque boost
invalid, please
setting about
P0.16=3% manual
torque boost
Please select correct P4.00to
Y
2 6 according to upon
variable torque load
Setting correct
P4.01 P4.08

Advertisement

Table of Contents
loading