V&T E5-H Series User Manual page 103

High performance universal inverter
Table of Contents

Advertisement

Pb.06
When Pb.08 and Pb.10 setting without integral function, UP/DN single step increase or decrease
frequency define by Pb.06.
Pb.07
For some special applications that longer acceleration/deceleration time is required, the function can be
used to determine magnification of acceleration/deceleration time that has been set. For example, if the
current
acceleration/deceleration
acceleration/deceleration time is 10 times as long as acceleration/deceleration time 0 when ×10 is
selected.
Pb.08
Operational panel
Pb.09
Setting with operational panel ∧/∨ regulating frequency can be realized by the function. When the
operational panel is in the parameter display state of operation or stop,through operational panel ∧/∨ to
regulate frequency is the most direct and covenient way. Frequency value will save in the inverter and
superimposed on other frequency as final frequency.
Operational panel ∧/∨ digital regulating frequency control Pb.08 determines the function of operation
panel ∧/∨ adjustment volume.
Operational panel
∧ ∨
for one time when adjusting with ∧/∨, that is, if you hold press the key for the time you have set for
Pb.09, the frequency will be changed after the time you have set.
96
E5−H High Performance Universal Inverter
Figure 6−35 High and low limit of Skip frequency
Single step without integral function
Magnification selection
Display of operation panel
Acceleration/deceleration time
Unit place
0:×1;
Tens place
Reserved
time
/
digital regulating frequency control
∧ ∨
Operational panel
integral rate Pb.09 determines the time it will take to refresh increment/decrement
/
Chapter 6 Parameter Description
1:×10
0(P0.08,
P0.09)
∧ ∨
/
inte
gral rate
User Manual
0.00~10.00Hz(0.1Hz)
00~01(00)
is
enabled,
the
0000~1221(0001)
0.1~50.0 s(2.0s)
real
applied