Multi−functional input terminal definition table:
SN
0
Jog forward
1
Jog reverse
2
Forward (FWD)
3
Reverse (REV)
4
Three−wire operation control
5
Reserved
6
Multi−section digital voltage terminal 1
7
Multi−section digital voltage terminal 2
8
Multi−section digital voltage terminal 3
9
Multi−section frequency terminal 1
10
Multi−section frequency terminal 2
11
Multi−section frequency terminal 3
12
Multi−section frequency terminal 4
13
Acceleration/deceleration terminal 1
14
Acceleration/deceleration terminal 2
15
Digital regulating frequency reset
16
Frequency increase instruction
17
Frequency decrease instruction
Acceleration
18
instruction
19
External failure input
20
Terminal failure reset input
21
External interrupt contact input
22
Inverter running disabled
23
Shutdown via terminal
24
Free shutdown via terminal
Relevant term explanation:
Terminal Xi: Refers to any of terminal X1, X2, X3, X4, also called terminal X.
Terminal Yi: Refers to terminal Y1or relay also called terminal Y.
Terminal function enabled: Means that terminal Xi has set the function under description. And P7.25
adopts the leave−factory value, the terminal is closed; when the P7.25 adopts the non−factory setting,
the terminal is open.
Terminal function disabled: Means that terminal Xi has not set the function under description; or it has set
the function, but when P7.25 adopts the leave−factory value, the terminal is open; or when the P7.25
adopts the non−factory setting, the terminal is closed.
The factory setting of terminal Xi (i=1~4) is no function (function code set to 99).
0: Terminal jog forward input
1: Terminal jog reverse input
2: Terminal forward run input (FWD)
3: Terminal reverse run input (REV)
The functions of above items 0 to 3 are only enabled when the running command is issued via terminal
(P0.06=1). Interlocking of running command and jog command means that the jog command will not be
E5−H High Performance Universal Inverter
Function definition
and
deceleration
disable
Chapter 6 Parameter Description
User Manual
SN
Function definition
25
Shutdown via terminal with DC braking 1
26
Emergent stop 1 (fastest shutdown)
27
Shutdown via terminal with DC braking 2
28
Counter trigger input
29
Counter trigger reset
30~31
Reserved
32
Forced wake up input
33~47
Reserved
48
Command switching to operation panel
49
Command switching to terminal
50
Command switching to host computer
Main frequency source close loop and open
51
loop switching input
52
Main frequency source switching to digital
53
Reserved
54
Main frequency source switching to AI1
55
Main frequency source switching to AI2
56~57
Reserved
Auxiliary frequency source switching to
58
disabled
59
Reserved
60
Auxiliary frequency source switching to AI1
61
Auxiliary frequency source switching to AI2
62~66
Reserved
67
Closed loop output forced to be 0
68
PID positive or negative function
69~98
Reserved