V&T E5-H Series User Manual page 54

High performance universal inverter
Table of Contents

Advertisement

Function
code
Function code name
number
Fault shield and alarm
PA.16
attribute setting 1
Fault shield and alarm
PA.17
attribute setting 2
Fault shield and alarm
PA.18
attribute setting 3
Fault locking function
PA.20
selection
PA.21
Automatic reset times
PA.22
Automatic reset interval
Skip frequency 1 low
Pb.00
limit
Skip frequency 1 high
Pb.01
limit
Skip frequency 2 low
Pb.02
limit
Skip frequency 2 high
Pb.03
limit
Skip frequency 3 low
Pb.04
limit
Skip frequency 3 high
Pb.05
limit
Single step under
Pb.06
without integral function
Pb.07
Magnification selection
Operation panel
Pb.08
digital regulating
frequency control
E5−H High Performance Universal Inverter
Factory
Setting range
setting
0020
0000 ~ 2222
0000
0000 ~ 2222
2000
0000 ~ 2222
0
0 ~ 1
0
0 ~ 20
2.0
2.0 ~20.0
Group Pb
0.00
0.00 ~ 300.00
0.00
0.00 ~ 300.00
0.00
0.00 ~ 300.00
0.00
0.00 ~ 300.00
0.00
0.00 ~ 300.00
0.00
0.00 ~ 300.00
0.1
0.0~10.00
00
00 ~ 01
/
∧ ∨
0001
0000 ~ 1221
Chapter 5 List of Parameters
Unit
Property
/
×
/
×
/
×
/
×
/
×
s
×
Enhanced Function Parameter
Hz
×
Hz
×
Hz
×
Hz
×
Hz
×
Hz
×
Hz
/
×
/
User Manual
Function code selection
LED ones place: Output−ground short
circuit
LED tens place: Power failure during
running process
LED hundreds place: Input power error
LED thousands place: Output phase
failure
0: Fault is not shileded, stopped upon
fault;
1: Fault is not shielded, non−stop upon
fault;
2: Fault is shielded, no alarm and no
stop
LED ones place: EEPROM error
LED tens place: Relay contact
open/close failure
LED hundreds place: Temperature
sensor taking sample anomaly
LED thousands place: Reserved
LED ones place: +10V output error
LED tens place: Analog input error
LED hundreds place: Motor over
temperature (PTC)
LED thousands place: Communication
failure 1(operation panel 485)
0: Fault is not shileded, stopped upon
fault;
1: Fault is not shielded, non−stop upon
fault;
2: Fault is shielded, no alarm and no
stop
0: Fault is not locked;
1: Fault is locked
0 ~ 20
2.0 ~ 20.0s
High / low frequency limit (P0.13 ~
P0.14)
High / low frequency limit (P0.13 ~
P0.14)
High / low frequency limit (P0.13 ~
P0.14)
High / low frequency limit (P0.13 ~
P0.14)
High / low frequency limit (P0.13 ~
P0.14)
High / low frequency limit (P0.13 ~
P0.14)
0.1~10.00 Hz
Ones place: Acceleration /
deceleration time
0: X1;
1: X10
Tens place: Reserved
Ones place: Action upon power off
0: Save upon power off;
1: Clear upon power off
Tens place: Action upon stopping
0: Hold upon stopping;
1: Clear upon stop;
User