Function
code
Function code name
number
Analog channel function
P6.21
selection
P6.22
AI1 filtering time
P6.23
AI2 filtering time
Y1 terminal output
P7.00
function selection
Relay terminal output
P7.02
function selection
AO1 terminal output
P7.03
function selection
AO2 terminal output
P7.04
function selection
P7.05
AO1 gain
P7.06
AO1 bias
P7.07
AO2 gain
P7.08
AO2 bias
Selection of positive
P7.09
and negative gain and
bias
P7.11
Output signal type
P7.12
Y1 terminal delay time
P7.13
Y1 terminal pulse width
Relay terminal delay
P7.16
time
Relay terminal pulse
P7.17
width
Zero current detection
P7.18
width
Frequency arrival
P7.19
detection width
P7.20
FDT1 level high limit
P7.21
FDT1 level low limit
P7.22
FDT2 level high limit
P7.23
FDT2 level low limit
Virtual terminal effective
P7.24
selection
44
E5−H High Performance Universal Inverter
Factory
Setting range
setting
00
0 ~ 66
0.004
0.000 ~ 1.000
0.004
0.000 ~ 1.000
Group P7
Multi−function Output Parameter
0
0 ~ 47
14
0 ~ 47
48
48 ~ 71
49
48 ~ 71
100.0
0.0 ~ 200.0
0.0
0.0 ~ 200.0
100.0
0.0 ~ 200.0
0.0
0.0 ~ 200.0
0000
0 ~ 1111
000
000 ~ 101
0.0
0.0 ~ 999.9
0.0
0.0 ~ 999.9
0.0
0.0 ~ 999.9
0.0
0.0 ~ 999.9
0.0
0.0 ~ 50.0
2.50
0.00 ~ 300.00
50.00
0.00 ~ 300.00
49.00
0.00 ~ 300.00
25.00
0.00 ~ 300.00
24.00
0.00 ~ 300.00
000
000 ~ 111
Chapter 5 List of Parameters
User Manual
Unit
Property
Function code selection
LED ones place: AI1 function selection
0: Open loop frequency or close loop
analog input;
1~4: Reserved;
/
×
5: Motor temperature feedback
(overload protective sensor);
6: Reserved;
LED tens place: AI2 function selection,
same with above
s
×
0.000 ~ 1.000s
s
×
0.000 ~ 1.000s
Refer to the definitions of multi
/
function digital outputs of P7 group,
and the definitions of multi function
/
analog values and pulse output in
Chapter 6.
/
/
%
0.0 ~ 200.0%
%
0.0 ~ 200.0%
%
0.0 ~ 200.0%
%
0.0 ~ 200.0%
Ones place: AO1 gain:
0: Positive;1: Negative
Tens place: AO1 bias:
0: Positive;1: Negative
/
Hundreds place: AO2 gain:
0: Positive;1: Negative
Thousands place: AO2 bias:
0: Positive;1: Negative
Ones place: Y1 terminal:
0: Level signal; 1: Pulse signal
/
×
Tens place: Reserved;
Hundreds place: Relay terminal:
0: Level signal; 1: Pulse signal
s
0.0 ~ 999.9s
s
0.0 ~ 999.9s
s
0.0 ~ 999.9s
s
0.0 ~ 999.9s
%
0.0 ~ 50.0%
Hz
0.00 ~ 300.00Hz
Hz
0.00 ~ 300.00Hz
Hz
0.00 ~ 300.00Hz
Hz
0.00 ~ 300.00Hz
Hz
0.00 ~ 300.00Hz
LED ones place: Multi function input
terminal Xi
0: Real terminal is enabled;
/
1: Virtual terminal is enabled
LED tens place: Reserved
LED hundreds place: Y1/Relay