Password Operation - V&T E5-H Series User Manual

High performance universal inverter
Table of Contents

Advertisement

4.4.5 Identify Symbols Displayed Via LED
The relationship between characters displayed by LED and characters/numbers are as follows:
Meanings of
LED display
characters
0
1
2
3
4
5
6
7
8
9

4.5 Password Operation

Set Password
Enter password function code and set to the identical parameters for two times continuously.
After "P.Set" is displayed, the password setting is successful. See 4.8.3 for password setting.
Password Verification
Enter password function code, enter password correctly and you can see the parameters
protected by password. See 4.8.4 descriptions of password verification.
Clear Password
After passing password verification, enter password function code, set 0000 continuously for two
times, "P. CLr" is displayed, this means the password is successfully cleared. From now on, you
need not enter password for access the password protection area. See 4.8.5 descriptions of
clearing password.
Method of Enabling Password
One of following three methods can be used to enable the password:
1. Press ESC+PRG +∧ at the same time (for shuttle type, turning clock wise is equivalent
to the ∧ key) to display "Prot". If key locking function is enabled, "Loc1" (P2.00=1) or
32
E5−H High Performance Universal Inverter
Meanings of
LED display
characters
A
b
C
c
d
E
F
G
H
h
Chapter 4 Using Instructions of Operation Panel
User Manual
Meanings of
LED display
characters
I
J
L
N
n
O
o
P
q
r
Meanings of
LED display
characters
S
T
t
U
V
y
8.
.