Bosch rexroth ctrlX SAFETY SafeMotion Applications Manual page 224

Table of Contents

Advertisement

ctrlX SAFETY "SafeMotion"
224 / 302
Machine acceptance test
identifier is entered in the header of the memo. In addition, the time at which
the memo was created and the time of the last modification are stored. The
"Comment" edit field allows entering a free text.
In the "Not relevant" column, the commissioning engineer can mark combina-
tions irrelevant due to the system configuration and thereby document why
these combinations were not checked. Changes made to the OK column and
the "Not relevant" column of the memo or to the comment are immediately
written to the memo file.
With the "Screenshot" button, a screenshot of the section highlighted below is
copied to the clipboard for the purpose of documentation:
Fig. 109: Machine acceptance test: Selection
The corresponding parameters are:
● P‑0‑3330.x.1, SMO: IO mapper inputs, type
● P‑0‑3330.x.2, SMO: IO mapper inputs, IDN source
● P‑0‑3330.x.3, SMO: IO mapper inputs, bit source
● P‑0‑3330.x.4, SMO: I/O mapper inputs, IDN target
● P‑0‑3330.x.5, SMO: I/O mapper inputs, bit target
Bosch Rexroth AG
R911404905, Edition 02

Advertisement

Table of Contents
loading