Dtc 1613- Microprocessor Failure - Rti 2 - JLG 1200SJP Service Maintenance Manual

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

DTC 1613- Microprocessor Failure - RTI 2

• Engine Control Module
• Check Condition- Key on
• Fault Condition- Internal microprocessor error
• MIL- On until code is cleared by technician
• Adaptive- Disabled for the remainder of the key-on cycle
• Closed Loop- Enabled
• Power Derate (level 2 until fault is cleared manually)
3121142
ECM
The ECM has checks that must be satisfied each time an
instruction is executed. Several different things can happen
within the microprocessor that will cause this fault. The ECM
will reset itself in the event this fault is set, and the MIL will be
on until the code is cleared. This fault should be erased after
diagnosis by removing battery power. It will not self-erase.
During this active fault, Power Derate (level 2) will be enforced.
When this is enforced, maximum throttle position will be 20%.
This is enforced until the fault is manually cleared.