JLG 1200SJP Service Maintenance Manual page 463

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

Flash
DTC
Sequence
Code
3372
33
72
3373
33
73
3374
33
74
3375
33
75
3376
33
76
3377
33
77
3378
33
78
3379
33
79
3380
33
80
3381
33
81
3385
33
85
3386
33
86
3387
33
87
3391
33
91
3392
33
92
3393
33
93
3394
33
94
3395
33
95
3396
33
96
3121142
Table 6-6. Diagnostic Trouble Code Chart
Fault Message
GROUND ALARM - OPEN CIRCUIT
GEN SET/WELDER - SHORT TO GROUND
GEN SET/WELDER - OPEN CIRCUIT
GEN SET/WELDER - SHORT TO BATTERY
HEAD TAIL LIGHT - SHORT TO GROUND
HEAD TAIL LIGHT - OPEN CIRCUIT
HEAD TAIL LIGHT - SHORT TO BATTERY
HOUR METER - SHORT TO GROUND
HOUR METER - OPEN CIRCUIT
HOUR METER - SHORT TO BATTERY
PLATFORM LEVEL UP OVERRIDE VALVE - SHORT TO GROUND
PLATFORM LEVEL UP OVERRIDE VALVE - OPEN CIRCUIT
PLATFORM LEVEL UP OVERRIDE VALVE - SHORT TO BATTERY
PLATFORM LEVEL DOWN OVERRIDE VALVE - SHORT TO GROUND
PLATFORM LEVEL DOWN OVERRIDE VALVE - OPEN CIRCUIT
PLATFORM LEVEL DOWN OVERRIDE VALVE - SHORT TO BATTERY
PLATFORM ROTATE LEFT VALVE - SHORT TO GROUND
PLATFORM ROTATE LEFT VALVE - OPEN CIRCUIT
PLATFORM ROTATE LEFT VALVE - SHORT TO BATTERY
Fault Description
There is an Open Circuit to the
Ground Alarm.
There is a Short to Ground to the
Generator Relay.
There is an Open Circuit to the
Generator Relay.
There is a Short to Battery to the
Generator Relay.
There is a Short to Ground to the
Head Light Relay.
There is an Open Circuit to the
Head Light Relay.
There is a Short to Battery to the
Head Light Relay.
There is a Short to Ground to the
Hour Meter.
There is an Open Circuit to the
Hour Meter.
There is a Short to Battery to the
Hour Meter.
There is a Short to Ground to the
Platform Level Up Override
Valve.
There is an Open Circuit to the
Platform Level Up Override
Valve.
There is a Short to Battery to the
Platform Level Up Override
Valve.
There is a Short to Ground to the
Platform Level Down Override
Valve.
There is an Open Circuit to the
Platform Level Down Override
Valve.
There is a Short to Battery to the
Platform Level Down Override
Valve.
There is a Short to Ground to the
Platform Rotate Left Valve.
There is an Open Circuit to the
Platform Rotate Left Valve.
There is a Short to Battery to the
Platform Rotate Left Valve.
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
Check
- Ground Alarm equipped vehicles
only.
- Generator / Welder equipped
vehicles only.
- Generator / Welder equipped
vehicles only.
- Generator / Welder equipped
vehicles only.
- Head Light equipped vehicles
only.
- Head Light equipped vehicles
only.
- Head Light equipped vehicles
only.
- Can be reported during power-
up.
- Electronic leveling system
equipped vehicles only.
- Electronic leveling system
equipped vehicles only.
- Electronic leveling system
equipped vehicles only.
- Electronic leveling system
equipped vehicles only.
- Electronic leveling system
equipped vehicles only.
- Electronic leveling system
equipped vehicles only.
6-87