SECTION 6 - JLG CONTROL SYSTEM

Load Moment Pin Troubleshooting

The following Troubleshooting Charts outline diagnostic mea-
sures to be taken to diagnose problems within the Load
Moment Pin portion of the JLG Control System. If necessary,
Table 6-10. Load Moment Pin Troubleshooting: Can Communications Lost
STEP
FAULT CODE/SYMPTOM
1
6/6 CYLINDER LOAD PIN CAN COMMUNICATIONS LOST
2
3
4
5
6
7
6-128
refer to Section 4 for information concerning replacement of
the Load Moment Pin.
REPAIR
Check for correct and tight wire connec-
tions at the deutsch and phoenix con-
nectors of the Load Sensing Pin harness
and perform a continuity check.
Check for loose pins in the potting of the
Boom Length & Angle Module J4 con-
nection.
Inspect the CANbus link "T" fitting con-
nections at the BLAM & Ground Module.
Are the fittings dry?
Inspect the CANbus link "T" fitting con-
nections at the BLAM & Ground Module.
Perform a continuity check.
Check the J1 and J4 plug connections on
the BLAM, make sure the notched plugs
line up with the plug sockets correctly.
Use the Analyzer, scroll – + to the DIAG-
NOSTICS menu, press ENTER, then scroll
to the MOMENT menu, and press ENTER,
check to see i f Actual / Over / Under
moment values are registering on the
screen display.
If they are, refer to Figure 6-32.,
Moment Chart for comparable values, if
the values are not close, try boom sen-
sor calibration to see if the values come
within the chart.
– JLG Lift –
YES
Go to step 2
Replace harness. (4922826)
Replace the BLAM &
Go to step 3
Perform the Boom Sen-
sor calibration process.
Go to step 4
Replace "T" fitting connector.
(4460945)
Go to step 5
Replace "T" fitting connector.
(4460945)
Go to step 6
Position plug correctly.
Go to step 6
Replace the load moment pin. &
Perform the Boom Sensor cali-
bration process.
If the problem still exists, verify
Replace the load moment pin. &
steps 1-7 again before contact-
Perform the Boom Sensor cali-
ing the JLG Service Dept.
bration process.
NO
3121142