Dtc 606- Microprocessor Failure - Cop - JLG 1200SJP Service Maintenance Manual

Hide thumbs Also See for 1200SJP:
Table of Contents

Advertisement

SECTION 3 - CHASSIS & TURNTABLE

DTC 606- Microprocessor Failure - COP

• Engine Control Module
• Check Condition- Key on
• Fault Condition- Internal microprocessor error
• Corrective Action(s) - Illuminate MIL and/or sound audible
warning or illuminate secondary warning lamp, disable
adaptive fueling correction for remainder of key cycle, rec-
ommend power derate 2 and low rev limit to reduce possi-
ble engine damage and/or overspeed condition
• Non-emissions related fault
3-164
ECM
The ECM has checks that must be satisfied each time an
instruction is executed. Several different things can happen
within the microprocessor that will cause this fault.
If this fault sets, the ECM will reset itself and log the code. The
fault should be configured to never forget and will not self-
erase and will not clear until a technician performs diagnostics
and manually clears the code. This fault should be configured
to set a power derate 2 and low rev limit to reduce possible
engine damage and reduce possibility of an overspeed condi-
tion.
– JLG Lift –
M icroprocessor
R A M
3121142

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350sjp

Table of Contents