4. The analyzer screen should read:
5. Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.
6. Enter the Access Code, 33271.
7. Go to the CALIBRATIONS menu and hit ENTER.
8. Go to the BASKET U CRKPT Screen. Hit ENTER.
9. CALIBRATE? prompt should appear. Hit ENTER again.
10. You will hear engine go to 1800 rpm.
3121142
11. Using UP ARROW, increase the value until you see the
basket up movement.
12. Hit ENTER again. CAL. COMPLETE message should
appear
13. Engine should again return to idle.
14. Hit ESC should return to BASKET U CRKPT screen.
15. Hit RIGHT ARROW to get to the "BASKET D CRKPT"
screen. Hit ENTER.
16. CALIBRATE? prompt should appear. Hit ENTER again.
17. You will hear engine go to 1800 rpm.
Using UP ARROW, increase the value until you see the basket
down movement.
Hit ENTER again. CAL. COMPLETE message should appear
Engine should again return to idle.
Hit ESC to exit.
Cycle power to the machine.

6.16 CALIBRATING LIFT CRACK POINT

1. Position the Platform/Ground select switch to the Plat-
form position.
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
6-59