HYDRAULIC SYSTEM
5.
Place your hand on the pump to check for excessive
heat buildup caused by binding or other problems. If the
pump is too hot to keep a hand on, stop the engine.
Each section should feel about the same warmth, but
pressure drops in each pump section's circuit would
explain some difference between sections.
6.
Listen for abnormal noises indicating low hydraulic oil
level or internal pump problems. If the pump is making
excessive noise, it is probably sucking air into its inlet,
keeping it from priming. In case of abnormal noise, stop
engine, and inspect the pump and the suction line for a
loose connection, a leak or a damaged or missing o-ring.
2-20
7.
8.
9.
10. Check pressure settings. Refer to Pressure Setting
Published 9-04-2014, Control # 422-08
RT765E-2 SERVICE MANUAL
If the pump seems to be running properly, increase the
rpm to 1500 to 1800 rpm for one to two minutes while
operating no hydraulic functions. Repeat checks in steps
4, 5, and 6.
Increase engine speed in steps to full RPM. Repeat
checks in steps 4, 5, and 6.
Cycle the components the pump sections power to verify
the pump sections drive them properly. Verify there is no
leaking.
Procedures, page 2-23.
6927-4
1
2
5
6927-3
3
4
FIGURE 2-4
Need help?
Do you have a question about the Grove RT765E-2 and is the answer not in the manual?
Questions and answers
Cummins QSB 6.7 diesel engine not starting
The provided context does not contain specific troubleshooting steps for why the Cummins QSB 6.7 diesel engine in the Manitowoc Grove RT765E-2 might not start. However, common reasons for a diesel engine failing to start include:
1. Fuel Issues – Low or contaminated fuel, clogged fuel filters, or air in the fuel system.
2. Battery Problems – Weak or dead battery preventing proper cranking.
3. Starter Motor Failure – Faulty starter preventing engine turnover.
4. DPF Regeneration Interruption – If the Diesel Particulate Filter (DPF) regeneration was interrupted, it could affect engine performance.
5. Electrical or Sensor Faults – Wiring issues, faulty sensors, or an inactive safety switch.
If the engine does not start, checking these possible causes is recommended.
This answer is automatically generated
Cummins diesel engine QSB 6.7 cranking but failing to start what could be the problem
Possible reasons why a Manitowoc Grove RT765E-2 with a Cummins QSB 6.7 diesel engine is cranking but failing to start could include:
1. Fuel Issues
- Insufficient or contaminated fuel.
- Clogged fuel filter or fuel lines.
- Faulty fuel pump preventing fuel delivery.
2. Air Intake Problems
- Blocked or restricted air filter.
- Turbocharger failure affecting air intake.
3. Electrical Issues
- Weak or faulty battery preventing proper cranking speed.
- Faulty starter motor or wiring connections.
- Malfunctioning engine control module (ECM).
4. Injection System Failure
- Faulty fuel injectors or injection pump.
- Air trapped in the fuel system.
5. Sensor or Control Failures
- Malfunctioning crankshaft or camshaft position sensor preventing proper timing.
- Faulty engine temperature sensor or other control module issues.
6. Low Oil Pressure or Safety Shutoff
- Engine protection systems preventing startup due to low oil pressure or other safety concerns.
Checking fuel supply, air intake, battery condition, and diagnostic codes can help identify the issue.
This answer is automatically generated