Sensor-Controlled Cleaning - wtw DIQ/S 182-MOD System Operating Manual

Modular measuring system for 2 digital sensors with modbus rtu/rs 485 output
Table of Contents

Advertisement

Relay outputs
Requirements
Settings
6 - 20

6.4.7 Sensor-controlled cleaning

With the Sensor controlled function, the relay is controlled by a linked
sensor.
 Controller version from 2.80
 Sensor that transmits signals to trigger a cleaning cycle, e.g. UV/VIS
sensor
Setting
Pulse length
Note
Settings of the cleaning process can be done in the SETTINGS menu
of the respective sensor.
Selection/Values
Automatic
0,5 s
1 s
2 s
3 s
System 182
Explanation
The duration of the air
cleaning process is
programmed in the
sensor.
The relay automati-
cally takes over the
cleaning duration
from the sensor.
The relay finishes the
cleaning after the
selected interval.
ba75504e07
04/2012

Advertisement

Table of Contents
loading

Table of Contents