Endress+Hauser Proservo NMS83 Operating Instructions Manual page 277

Tank gauging
Hide thumbs Also See for Proservo NMS83:
Table of Contents

Advertisement

Proservo NMS83
Additional information
Slow hoist zone
Navigation
Description
User entry
Factory setting
Additional information
Overtension weight
Navigation
Description
User entry
Factory setting
Additional information
Undertension weight
Navigation
Description
User entry
Factory setting
Endress+Hauser
Read access
Write access
 Setup → Advanced setup → Safety settings → Slow hoist zone
Defines the interval in millimeters, measured down from the Reference Position, in which
the Displacer reduces moving speed.
–999 999.9 to 999 999.9 mm
70 mm
Read access
Write access
 Setup → Advanced setup → Safety settings → Overtension wgt
Sets the minimum Weight in grams when Overtension Alarm will be set.
100 to 999.9 g
350 g
Read access
Write access
 Setup → Advanced setup → Safety settings → Undertension wgt
Defines the undertension error weight. Untertension error will be issued if displacer
weight is below this value longer than 7 seconds.
0 to 300 g
10 g
Operator
Maintenance
Operator
Maintenance
Operator
Maintenance
Operating menu