Endress+Hauser Proservo NMS83 Operating Instructions Manual page 238

Tank gauging
Hide thumbs Also See for Proservo NMS83:
Table of Contents

Advertisement

Operating menu
Water level source
Navigation
Description
Selection
Factory setting
Additional information
Manual water level
Navigation
Prerequisite
Description
User entry
Factory setting
Additional information
Water level
Navigation
Description
238
The device adjusts the Empty parameter (→  170) according to the entered value, such
that the measured level will match the actual level.
 Setup → Advanced setup → Application → Tank config → Level → Water level src
Defines the source of the bottom water level.
• Manual value
• Bottom level
• HART device 1 ... 15 level
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Manual value
Read access
Write access
 Setup → Advanced setup → Application → Tank config → Level → Man. water level
Water level source (→  238) = Manual value
Defines the manual value of the bottom water level.
–2 000 to 5 000 mm
0 mm
Read access
Write access
 Setup → Advanced setup → Application → Tank config → Level → Water level
Shows the bottom water level.
Operator