Operating menu
User entry
Factory setting
Additional information
Low stop level
Navigation
Description
User entry
Factory setting
Additional information
Distance
Navigation
Description
Additional information
Liquid temp source
Navigation
Description
Selection
Factory setting
172
–999 999.9 to 999 999.9 mm
Dependent on the device version
Read access
Write access
Setup → Low stop level
Position of the displacer low stop as measured from defined zero position (tank bottom or
datum plate).
–999 999.9 to 999 999.9 mm
0 mm
Read access
Write access
Setup → Distance
Shows measured distance from reference position.
Read access
Write access
Setup → Liq temp source
Defines source from which the liquid temperature is obtained.
• No input value
• HART device 1 ... 15 temperature
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
No input value