Initial Settings - Endress+Hauser Proservo NMS83 Operating Instructions Manual

Tank gauging
Hide thumbs Also See for Proservo NMS83:
Table of Contents

Advertisement

Proservo NMS83
Endress+Hauser
14
Mechanical stop
15
Slow hoist zone
16
Distance
17
Reference position
9.2

Initial settings

Depending on NMS8x specification, some of the initial settings described below may not
be required.
9.2.1
Setting the display language
Setting the display language via the display module
1. While in the standard view (→  53), press "E". If required, select Keylock off from
the context menu and press "E" again.
 The Language parameter appears.
2. Open the Language parameter and select the display language.
Setting the display language via an operating tool (e.g. FieldCare)
1. Navigate to: Setup → Advanced setup → Display → Language
2. Select the display language.
This setting only affects the language on the display module. To set the language in
the operating tool use the language setting functionality of FieldCare or DeviceCare,
respecitvely.
9.2.2
Setting the real-time clock
Setting the real-time clock via the display module
1. Navigate to: Setup → Advanced setup → Date / time → Set date
2. Use the following parameters to set the the real-time clock to the current date and
time: Year, Month, Day, Hour, Minutes.
Setting the real-time clock via an operating tool (e.g. FieldCare)
1. Navigate to: Setup → Advanced setup → Date / time
2.
Go to the Set date parameter and select the Start option.
Commissioning