Endress+Hauser Proservo NMS83 Operating Instructions Manual page 243

Tank gauging
Hide thumbs Also See for Proservo NMS83:
Table of Contents

Advertisement

Proservo NMS83
Observed density source
Navigation
Description
Selection
Factory setting
Additional information
Density value
Navigation
Description
Additional information
Air density
Navigation
Description
User entry
Factory setting
*
Visibility depends on order options or device settings
Endress+Hauser
"Density" submenu
Navigation
 Setup → Advanced setup → Application → Tank config
 Setup → Advanced setup → Application → Tank config → Density → Density source
Determines how the density is obtained.
• HTG
• HTMS
• Average profile density
• Upper density
• Middle density
• Lower density
Dependent on the device version
Read access
Write access
 Setup → Advanced setup → Application → Tank config → Density → Density value
Shows the measured or calculated density.
Read access
Write access
 Setup → Advanced setup → Application → Tank config → Density → Air density
Defines the density of the air surrounding the tank.
0.0 to 500.0 kg/m³
1.2 kg/m³
→ Density
*