Installation
22
-1.4 -1.3 -1.2 -1.1 -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0.0 0.1 0.2 0.3
-36
-32
0
0
2000
100
4000
200
6000
300
8000
10000
400
12000
500
14000
600
16000
700
18000
20000
800
22000
900
24000
1000
26000
1100
28000
30000
1200
32000
1300
34000
1400
36000
38000
1500
40000
1600
42000
1700
44000
1800
46000
48000
8
Lateral shift of displacer according to measurement range
a
16 m (G1) (NMS80/NMS81/NMS83)
b
22 m (F1) (NMS80/NMS81/NMS83)
c
28 m (D1) (NMS80/NMS81)
d
36 m (C2) (NMS80/NMS81)
e
47 m (A3) (NMS81)
Upper diameter of stilling well
The dimension of D
has to be the largest value of the dimensions D
1
according to the following formula.
D
Dimension
D
Dimension
1
1x
(Example)
Example
>68.1 mm
68.1 mm
(2.68 in)
(2.68 in)
65.6 mm
(2.58 in)
50.9 mm
(2.00 in)
Example: L
= 1 000 mm, L
1
p (Lx) (mm) ( )
-28
-24
-20
-16
a
Description
Parameter
D
D
dimension when the
1a
1
displacer is in L
1
D
D
dimension when the
1b
1
displacer is in L
1
D
D
dimension when the
1c
1
displacer is in L
2
D
D
dimension when the radial
1d
1
direction offset is considered.
This calculation is used only
with the 47 m (156.67 ft) wire
drum (G1 in Feature110)
= 20 000 mm, d = 50 mm, s = 5.0, 28 m drum
2
Proservo NMS83
in
-12
-8
-4
0
b
c
d
e
, D
, D
1a
1b
1c
Formula
= 2 x ( |p (0)|+ d/2 + s)
= 0
= 2 x (|p (L
)|+ d/2 + s)
1
length
= 2 x ( |p (L
)|+ s)
2
length
= 2 x (d/2 + r + s)
Endress+Hauser
4
8
A0027997
, and D
1d
Need help?