Endress+Hauser CYR52 Operating Instructions Manual
Endress+Hauser CYR52 Operating Instructions Manual

Endress+Hauser CYR52 Operating Instructions Manual

Ultrasonic cleaning
Hide thumbs Also See for CYR52:

Advertisement

Quick Links

BA01300C/07/EN/03.22-00
71569939
2022-04-15
Products
Operating Instructions
CYR52
Ultrasonic cleaning
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYR52 and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser CYR52

  • Page 1 Products Solutions Services BA01300C/07/EN/03.22-00 71569939 2022-04-15 Operating Instructions CYR52 Ultrasonic cleaning...
  • Page 3: Table Of Contents

    CYR52 Table of contents Table of contents About this document ... 4 Accessories ....28 Warnings .
  • Page 4: About This Document

    About this document CYR52 About this document Warnings Structure of information Meaning This symbol alerts you to a dangerous situation. DANGER Failure to avoid the dangerous situation will result in a fatal or serious injury. Causes (/consequences) If necessary, Consequences of non- compliance (if applicable) ‣...
  • Page 5: Basic Safety Instructions

    Intended use The CYR52 ultrasonic cleaning system is used to clean turbidity sensors in liquids that are installed in pipes. Use of the device for any purpose other than that described, poses a threat to the safety of people and of the entire measuring system and is therefore not permitted.
  • Page 6: Product Safety

    Basic safety instructions CYR52 Product safety 2.5.1 State-of-the-art technology The product is designed to meet state-of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate. The relevant regulations and international standards have been observed.
  • Page 7: Product Description

    CYR52 Product description Product description Product design 3.1.1 Measuring system A complete measuring system comprises: • Ultrasonic generator • Ultrasonic transducer • Assembly or pipe with turbidity sensor • Liquiline CM44x transmitter A0038480  1 Ultrasonic cleaning with Flowfit CUA252 assembly...
  • Page 8 Product description CYR52 3.1.2 Ultrasonic transducer with Flowfit CUA252 flow assembly A0039566  2 Ultrasonic transducer on Flowfit CUA252 assembly 3.1.3 Ultrasonic transducer with Flowfit CUA262 flow assembly A0039567  3 Ultrasonic transducer on Flowfit CUA262 assembly Endress+Hauser...
  • Page 9 CYR52 Product description 3.1.4 Ultrasonic transducer with assembly of CUS31 A0039571  4 Ultrasonic transducer with assembly of CUS31 3.1.5 Ultrasonic transducer on pipe A0039569  5 Ultrasonic transducer mounted on pipe Endress+Hauser...
  • Page 10: Incoming Acceptance And Product Identification

    Incoming acceptance and product identification CYR52 Incoming acceptance and product identification Incoming acceptance Verify that the packaging is undamaged.  Notify the supplier of any damage to the packaging. Keep the damaged packaging until the issue has been resolved. Verify that the contents are undamaged.
  • Page 11: Scope Of Delivery

    Click the product overview.  A new window opens. Here you fill information pertaining to your device, including the product documentation. 4.2.3 Manufacturer address Endress+Hauser Conducta GmbH+Co. KG Dieselstraße 24 D-70839 Gerlingen Scope of delivery The scope of delivery comprises: •...
  • Page 12: Mounting

    Mounting CYR52 Mounting Mounting requirements 5.1.1 Dimensions of the ultrasonic transducer Ø 88 (3.46) Ø 6 (0.24) Ø 6 (0.24) 83 (3.27) 104 (4.09) 108 (4.25) CUA252 CUA262 A0022750  6 Dimensions for CUA252 and CUA262. Engineering unit: mm (in) ‣...
  • Page 13 CYR52 Mounting Ø 88 (3.46) Ø 6 (0.24) 120 (4.72) 140 (5.51) A0022753  7 Dimensions for assembly of CUS31. Engineering unit: mm (in) Endress+Hauser...
  • Page 14 Mounting CYR52 Ø 88 (3.46) 125 (4.92) 105 (4.13) A0022756  8 Dimensions for pipe mounting. Engineering unit: mm (in) Endress+Hauser...
  • Page 15 CYR52 Mounting 5.1.2 Dimensions of ultrasonic generator 199 (7.38) 128 (5.04) 237 (9.33) A0022755  9 Engineering unit: mm (in) Endress+Hauser...
  • Page 16 Mounting CYR52 Mounting plate 4 x 6.5 (0.26) 80 (3.15) 125 (4.92) A0012426  10 Mounting plate. Engineering unit: mm (in) Weather protection cover NOTICE Effect of climatic conditions (rain, snow, direct sunlight etc.) Possibility of impaired operation to complete failure of the ultrasonic generator! ‣...
  • Page 17: Mounting The Ultrasonic Transducer

    CYR52 Mounting Mounting the ultrasonic transducer CAUTION Substances in the sealant Irritation to eyes and skin! ‣ Do not inhale aerosols if used. ‣ Avoid contact with the eyes and skin. ‣ Wear protective gloves, protective goggles and protective clothing when using the sealant.
  • Page 18: Mounting The Ultrasonic Generator

    Mounting CYR52 Mounting the ultrasonic generator 5.3.1 Post mounting You require the post mounting kit (optional) to mount the unit on a pipe, post or railing (round or square, clamping range 20 to 60 mm (0.79 to 2.36 in)). A0033044 ...
  • Page 19 CYR52 Mounting A0033045 A0038625  13 Post mounting  14 Attach the device and click it into place Place the device on the mounting plate. Slide the device downwards in the guide on the mounting rail until it clicks into place.
  • Page 20 Mounting CYR52 A0025886 A0038628  16 Rail mounting  17 Attach the device and click it into place Place the device on the mounting plate. Slide the device downwards in the guide on the mounting rail until it clicks into place.
  • Page 21: Post-Mounting Check

    CYR52 Mounting A0027799 A0038631  20 Wall mounting  21 Attach the device and click it into place Place the device on the mounting plate. Slide the device downwards in the guide on the mounting rail until it clicks into place.
  • Page 22: Electrical Connection

    Electrical connection CYR52 Electrical connection WARNING Device is live! Incorrect connection may result in injury or death! ‣ The electrical connection may be performed only by an electrical technician. ‣ The electrical technician must have read and understood these Operating Instructions and must follow the instructions contained therein.
  • Page 23: Post-Connection Check

    CYR52 Electrical connection Connect the ultrasonic cleaning system in the following order: Connect the control cable (not included in the scope of delivery, H03VV-F 2x0.75 is recommended) to terminals 1 and 2 at the ultrasonic generator. Connect the control cable to a free relay at the transmitter at terminals 41 and 42.
  • Page 24: Commissioning

    Commissioning CYR52 Commissioning Function check WARNING Incorrect connection, incorrect supply voltage Safety risks for staff and device malfunctions! ‣ Check that all connections have been established correctly in accordance with the wiring diagram. ‣ Ensure that the supply voltage matches the voltage indicated on the nameplate.
  • Page 25: Diagnostics And Troubleshooting

    CYR52 Diagnostics and troubleshooting Diagnostics and troubleshooting General troubleshooting Error Possible cause Test Cleaning effect diminishes Ultrasonic cleaning system is Acoustic check (if the ultrasonic transducer hums defective during the cleaning process, the cleaning is working) The position of the ultrasonic...
  • Page 26: Maintenance

    Maintenance CYR52 Maintenance WARNING Process pressure and temperature, contamination, electrical voltage Risk of serious or fatal injury ‣ If the sensor has to be removed during maintenance work, avoid hazards posed by pressure, temperature and contamination. ‣ De-energize the device before opening it.
  • Page 27: Repair

    The product must be returned if repairs or a factory calibration are required, or if the wrong product was ordered or delivered. As an ISO-certified company and also due to legal regulations, Endress+Hauser is obliged to follow certain procedures when handling any returned products that have been in contact with medium.
  • Page 28: Accessories

    Accessories CYR52 Accessories The following are the most important accessories available at the time this documentation was issued. ‣ For accessories not listed here, please contact your Service or Sales Center. CYY101 • Weather protection cover for field devices • Absolutely essential for field installation •...
  • Page 29: Technical Data

    CYR52 Technical data Technical data 12.1 Output 12.1.1 Operating frequency Operating frequency of the ultrasonic cleaning system: approx. 40 kHz 12.2 Power supply 12.2.1 Supply voltage Depends on the order version: • 230 VAC ± 10 %, 50/60 Hz • 115 VAC ± 10 %, 50/60 Hz 12.2.2...
  • Page 30 Technical data CYR52 12.4.2 Weight Ultrasonic transducer: 0.72 kg (1.59 lb), with 3 m (9.8 ft) cable Ultrasonic generator: 2.2 kg (4.85 lb) 12.4.3 Materials Ultrasonic transducer Cover: Floor: Aluminum Cable: TPE-U mix; 3xLi9Y 0.75; sheath: Ø 6.6 mm (0.26 in) Minimum bending radius: 66 mm (2.6 in)66 mm (2.6 inch) when cable can...
  • Page 31: Index

    CYR52 Index Index Accessories ..... 28 Post-connection check ....23 Power supply .
  • Page 32 *71569939* 71569939 www.addresses.endress.com...

Table of Contents