Power Problems

All Maxor receivers are preset in the factory as "Auto Mode" for both the power
and charger. If you want to check these settings,
1.
2.
3.
These fields should be set to Auto. If not, change them to Auto and click
Apply.
Tip: Clearing the NVRAM will also return the receiver to
Auto Mode (see "Clearing the NVRAM" on page 4-17).
The receiver does not power up.
The receiver may be in
Zero Power Mode.
If no external power
source used, batteries
may be discharged.
The receiver has an
external power source,
but internal batteries are
discharged.
The receiver may have a
defective
defective
batteries.
www.javad.com
Connect your receiver and computer and run PCView (see "Connecting the
Maxor and a Computer" on page 2-9).
Once connected, click Configuration->Receiver.
On the General tab, view the Power and Charger fields.
Causes
charger
or
internal
Problem
Press the Reset key.
Connect a fully charged external power source and retry. See
"Powering the Maxor" on page 2-2.
Charge the batteries overnight. See"Powering the Maxor" on
page 2-2.
If after charging your internal batteries overnight, and your
Maxor is not powering, contact JNS Customer Support for
advice.
TR O U B L E S H O O T I N G

Power Problems

Solutions
Maxor Operator's Manual 5-3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maxor and is the answer not in the manual?

Related Products for Javad Maxor

This manual is also suitable for:

Maxor ggdt

Table of Contents