Goodrive20-UL Series VFD
Function
Name
code
Polarity
selection
P06.05
of output
terminals
Y1 open
P06.06
delay time
Y1C off
P06.07
delay time
RO1
switching
P06.10
on delay
time
RO1
switching
P06.11
off delay
time
RO2
switching
P06.12
on delay
time
RO2
switching
P06.13
off delay
time
AO1
P06.14
output
selection
AO2
P06.15
output
selection
Description
The function code is used to set the pole of the
output terminal.
When the current bit is set to 0, input terminal is
positive.
When the current bit is set to 1, input terminal is
negative.
BIT3
BIT2
RO2
RO1
Setting range: 0–F
Setting range: 0.000–50.000s
Setting range: 0.000–50.000s
The function code defines the corresponding
delay time of the electrical level change during
the programmable terminal switching on and off.
RO electrical level
Invalid
RO valid
Switch-on
delay
Setting range: 0.000–50.000s
Note: P06.08 and P06.08 are valid only when
P06.00=1.
0: Running frequency
1: Setting frequency
2: Ramp reference frequency
3: Running rotation speed (relative to twice the
rotation speed of the motor)
4: Output current (relative to twice the rated
current of the VFD)
5: Output current (relative to twice the rated
current of the motor)
6: Output voltage (relative to 1.5 times the rated
BIT1
Reserved
Invalid
Valid
Switch-off
delay
-61-
Function parameters
Default
0
BIT0
Y1
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0
0
Modify
○
○
○
○
○
○
○
○
○