People Counting
1. Go to Main Menu > VA > Parameters > People Counting > People
Figure 199 People Counting
2. Draw people counting rule.
Figure 200 Draw People Counting Rule
Table 82 People Counting Parameters
Parameter
Name
Duration
Filter target
Performance Series Embedded NVR User Guide
Counting.
The People Counting interface is displayed.
a. Click
to draw people counting rule.
b. Configure parameters.
Description
Customize the rule name.
Set the minimum time that the object stays until the alarm is triggered.
Click
of the area with the mouse.
Each rule can set 2 target filters (maximum size and minimum size), that
is, when the passing target is smaller than the minimum target or larger
than the maximum target, no alarm will be generated. The maximum size
should not be smaller than the minimum size.
c. Click and hold the left mouse key to draw an area for people
counting.
to filter the target. Check the blue wireframe and adjust the size
179