Fuel Dispensers TATSUNO EUROPE ‐ Installation and User Manual , revision 10, January 2022
2.3. BASIC TECHNICAL PARAMETERS
Table 8 – Dispensers and modules (gasoline, diesel, biodiesel, mixed diesel, E85, aircraft fuel)
Pumping performance
Maximum flow rate Q
[L/min]
max
Minimum flow rate Q
[L/min]
min
Lowest metering MMQ [L]
Maximum pressure [MPa] ‐ suction version
‐ pressure version
Minimum pressure [MPa]
Maximum unit price (number of digits)
Maximum amount to pay (number of digits)
Maximum volume (number of digits)
Scale interval [L]
Display type
Type of delivered fluid
Liquid dynamic viscosity range [mPa.s]
Filtration of mechanical particles
Fluid temperature range [°C]
Ambient temperature range [°C]
Accuracy class
Mechanical class
Electromagnetic class
Humidity
Location
Measured unit
Electronic counter
Program version (W&M check sum)
Calculator powering
Pump electric motor
Electro‐magnetic valves
*
Flow rate range Q
: Q
must be 10:1
max
min
**
Data transmission of the entire contents of the display with the number of digits 7/6.5/5 is only possible using the extended communication protocol (8/8/6)
***
The temperature range of the liquid is defined by the range of the measuring temperature sensor
Table 9 ‐ LPG (liquefied propane butane) dispensers and modules
Maximum flow rate Q
[L/min]
max
Minimum flow rate Q
[L/min]
min
Lowest metering MMQ [L]
Maximum pressure [MPa]
Minimum pressure [MPa]
Maximum unit price (number of digits)
Maximum amount to pay (number of digits)
Maximum volume (number of digits)
Scale interval [L]
Display type
Type of delivered fluid
Filtration of mechanical particles
Fluid temperature range [°C]
Ambient temperature range [°C]
Accuracy class
Mechanical class
Electromagnetic class
Humidity
Location
Measured unit
Electronic counter
Program version (W&M check sum)
Calculator powering
Electro‐magnetic valves
*
Data transmission of the entire contents of the display with the number of digits 7/6.5/5 is only possible using the extended communication protocol (8/8/6)
Standard
30 to 50
*
3 to 5
2
0.18
0.35
0.16
**
9999(4) or 99999(5)
**
999999(6) or 9999999(7)
**
999999(6) or 1999999(6.5)
0.01
Electronic
Gasoline, diesel, biodiesel, mixed diesel, ethanol (E85), aircraft fuel (AVGAS)
0,5 to 10
Pump inlet filter > 100μm; pump outlet filter > 70μm
**
‐20° to +50
‐20 to +40 (standard dispenser version); ‐40 to +55 (special dispenser version)
0.5
M1, M2 for counters PDEX5 and TBELTx
E1, E2 for the counter PDEX5
Condensing
Open
Volume [L] or volume at 15 °C [L]
TBELTx
PDEX
1.01 (8CA4)
1.03 (20260)
230V ± 10 %; 50Hz; max. 300VA
3x400V/230V; 50Hz; 0.75kW; 1410 rpm
Proportional; +24V DC/max. 1A
30 to 50
5
5
1.8
0.7
*
9999(4) or 99999(5)
*
999999(6) or 9999999(7)
*
999999(6) or 1999999(6.5)
0.01
Electronic
LPG (liquefied propane‐butane)
Input filter >25µm
‐20 to +40
‐20 to +40
1.0
M1, M2 for counters PDEX5 and TBELTx
E1, E2 for the counter PDEX5
Condensing
Open
Volume [L] or volume at 15 °C [L]
TBELTx
PDEX
1.01 (8CA4)
1.03 (20260)
230V ± 10%; 50Hz; max. 300VA
Proportional or two‐state; + 24VDC / max.1A
27
Increased (/H)
70 to 80
5
5
0.25
PDEX5
1.01 (4573), 1.02 (dbd2FFA4)
TBELTM
PDEX5
1.01 (4092)
1.01 (4573), 1.02 (dbd2FFA4)
Very high (/UH)
120 to 170
10
10
0.25