Basic Technical Parameters - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

Fuel Dispensers TATSUNO EUROPE ‐ Installation and User Manual  ,  revision 10, January 2022 
2.3. BASIC TECHNICAL PARAMETERS 
 
Table 8 – Dispensers and modules (gasoline, diesel, biodiesel, mixed diesel, E85, aircraft fuel) 
Pumping performance 
Maximum flow rate Q
[L/min] 
max 
Minimum flow rate Q
[L/min] 
min 
Lowest metering MMQ [L] 
Maximum pressure [MPa] ‐ suction version 
                                                ‐ pressure version 
Minimum pressure [MPa] 
Maximum unit price (number of digits) 
Maximum amount to pay (number of digits) 
Maximum volume (number of digits) 
Scale interval [L] 
Display type 
Type of delivered fluid 
Liquid dynamic viscosity range [mPa.s] 
Filtration of mechanical particles 
Fluid temperature range [°C] 
Ambient temperature range [°C] 
Accuracy class 
Mechanical class 
Electromagnetic class 
Humidity 
Location 
Measured unit 
Electronic counter 
Program version (W&M check sum) 
Calculator powering  
Pump electric motor 
Electro‐magnetic valves 
*
Flow rate range Q
:  Q
 must be 10:1 
max
min
** 
Data transmission of the entire contents of the display with the number of digits 7/6.5/5 is only possible using the extended communication protocol (8/8/6) 
***
The temperature range of the liquid is defined by the range of the measuring temperature sensor 
Table 9 ‐ LPG (liquefied propane butane) dispensers and modules 
Maximum flow rate Q
[L/min] 
max 
Minimum flow rate Q
[L/min] 
min 
Lowest metering MMQ [L] 
Maximum pressure [MPa] 
Minimum pressure [MPa] 
Maximum unit price (number of digits) 
Maximum amount to pay (number of digits) 
Maximum volume (number of digits) 
Scale interval [L] 
Display type 
Type of delivered fluid 
Filtration of mechanical particles 
Fluid temperature range [°C] 
Ambient temperature range [°C] 
Accuracy class 
Mechanical class 
Electromagnetic class 
Humidity 
Location 
Measured unit 
Electronic counter 
Program version (W&M check sum) 
Calculator powering  
Electro‐magnetic valves 
Data transmission of the entire contents of the display with the number of digits 7/6.5/5 is only possible using the extended communication protocol (8/8/6)
Standard 
30 to 50 
*
3 to 5
 
0.18 
0.35 
0.16  
 **
9999(4) or 99999(5)
 
**
999999(6) or 9999999(7) 
 
**
999999(6) or 1999999(6.5) 
 
0.01 
Electronic 
Gasoline, diesel, biodiesel, mixed diesel, ethanol (E85), aircraft fuel (AVGAS) 
0,5 to 10  
Pump inlet filter > 100μm; pump outlet filter > 70μm   
**
‐20° to +50
 
‐20 to +40 (standard dispenser version); ‐40 to +55 (special dispenser version) 
0.5 
M1, M2 for counters PDEX5 and TBELTx 
E1, E2 for the counter PDEX5 
Condensing 
Open 
Volume [L] or volume at 15 °C [L] 
TBELTx 
PDEX 
1.01 (8CA4) 
1.03 (20260) 
230V ± 10 %; 50Hz; max. 300VA 
3x400V/230V; 50Hz; 0.75kW; 1410 rpm 
Proportional; +24V DC/max. 1A 
30 to 50 
1.8 
0.7  
 *
9999(4) or 99999(5)
 
*
999999(6) or 9999999(7) 
 
*
999999(6) or 1999999(6.5) 
 
0.01 
Electronic 
LPG (liquefied propane‐butane) 
Input filter >25µm  
‐20 to +40 
‐20 to +40 
1.0 
M1, M2 for counters PDEX5 and TBELTx 
E1, E2 for the counter PDEX5 
Condensing 
Open 
Volume [L] or volume at 15 °C [L] 
TBELTx 
PDEX 
1.01 (8CA4) 
1.03 (20260) 
230V ± 10%; 50Hz; max. 300VA 
Proportional or two‐state; + 24VDC / max.1A 
27
Increased (/H) 
70 to 80 
0.25 
PDEX5 
1.01 (4573), 1.02 (dbd2FFA4) 
TBELTM 
PDEX5 
1.01 (4092) 
1.01 (4573), 1.02 (dbd2FFA4) 
Very high (/UH) 
120 to 170 
10 
10 
0.25 
 
 