4.1.8. FUEL PRODUCT UNIT PRICES (P03)
This feature allows you to view and set current unit prices (i.e., one litre of fuel) of all fuel products. These
fuel unit prices are set on the display at the first lift of the delivery nozzle and reset of the display if the
dispenser works in the manual mode. Setting is made by pressing the <E> key and entering the price in
the <PPPP> format and confirming by the <E> key. The decimal point is not entered. E.g., unit price 1.03
€/L is entered as number 0103, price 34.15 CZK/L as number 3415, etc.
Parameter
Meaning
P03‐1
fuel product unit price 1
P03‐2
fuel product unit price 2
P03‐3
fuel product unit price 3
P03‐4
fuel product unit price 4
P03‐5
fuel product unit price 5
NOTE
Number of fuel products shown in the P03 parameter is conditioned by the configuration of the dispenser.
The identification system of delivery hoses and products is described in Figure 77. if you change the unit price, such
change will be reflected after a subsequent lift of the delivery nozzle.
NOTICE
Values set in the P03 parameter are valid in the dispenser manual mode only. If the dispenser is
connected to the central control system of the fuel station, then the fuel unit price is set directly by the control
system before each delivery. In such case the values of the P03 parameter are non‐functional.
NOTICE
The dispenser does not enable deliveries with a zero value of the unit price. In such case, after lifting
the delivery nozzle the dispenser display shows the error message E30 and the delivery does not start.
4.1.9. CURRENT TIME AND DATE (P04)
This function allows to view and set the current time and date. The setting is made
by pressing the <E> key by entering the time/date in the correct format and
confirming with the <E> key.
Parameter
Meaning
P04‐1
Time setting, format HHMMSS (i.e., 125600 = 12:56:00)
P04‐2
Date setting, format DDMMYY (i.e., 230821 = 23. 08. 2021)
NOTE
The time/date information is used by parameters P20 to P34 to record the exact moment of the fault, end
of delivery, change of dispenser control mode..., etc. The date/time data has only an informative function, it does
not affect the process of fuel delivery.
NOTICE
The internal clock is reset at least 5 days after the power supply off. Time and date values will switch to
factory setting and must be set again!
116
TATSUNO EUROPE a.s., www.tatsuno‐europe.com
Factory setting
Factory setting
0:00:00
1.1.2001
0,00 €/L
0,00 €/L
0,00 €/L
0,00 €/L
0,00 €/L
time
125600
P04‐1
date
230821
P04‐2