4.1.13. SERIAL NUMBERS OF THE PERIPHERAL UNITS (P10) 
 The parameter is used to display the serial numbers of the connected peripheral units. The actual serial 
numbers  of  the  peripheral  units  are  compared  with  the  numbers  stored  in  the 
processor unit memory. If a mismatch is detected, an error message is displayed 
and fuel delivery is not allowed. The list of periphearal units is below. 
Example:  Parameter P10‐1, serial number of the main processor unit SN: 18‐00101 (see picture)
Parameter 
Peripheral unit 
P10‐1 
Main processor unit 
P10‐2 
Main temperature sensors unit PDEINP1 (for temp. sensors 1 to 4) 
P10‐3 
Auxiliar temperature sensors unit PDEINP2 (for temp. sensors 5 to 8) 
P10‐4 
Mass meter A 
P10‐5 
Mass meter B 
P10‐6 
Main displaying unit (Master) of filling point A 
P10‐7 
Auxiliar displaying unit (Slave) of filling point A 
P10‐8 
Main electromechanical totalizers unit (Master) of filling point A 
P10‐9 
Auxiliar electromechanical totalizers unit (Slave) of filling point A 
P10‐10 
Main displaying unit (Master) of filling point B 
P10‐11 
Auxiliar displaying unit (Slave) of filling point B 
P10‐12 
Main electromechanical totalizers unit (Master) of filling point B 
P10‐13 
Auxiliar electromechanical totalizers unit (Slave) of filling point B 
P10‐14 
Main displaying unit (Master) of filling point C 
P10‐15 
Auxiliar displaying unit (Slave) of filling point C 
P10‐16 
Main electromechanical totalizers unit (Master) of filling point C 
P10‐17 
Auxiliar electromechanical totalizers unit (Slave) of filling point C 
P10‐18 
Main displaying unit (Master) of filling point D 
P10‐19 
Auxiliar displaying unit (Slave) of filling point D 
P10‐20 
Main electromechanical totalizers unit (Master) of filling point D 
P10‐21 
Auxiliar electromechanical totalizers unit (Slave) of filling point D 
P10‐22 
Pressure sensors unit PDEDPS with address 1 
P10‐23 
Pressure sensors unit PDEDPS with address 2 
P10‐24 
Pressure sensors unit PDEDPS with address 3 
P10‐25 
Pressure sensors unit PDEDPS with address 4 
4.1.14. VAPOUR RECOVERY USER TEST DURATION – DRY TEST (P11) 
 The  parameter  specifies  the  test  duration  in  seconds for  which  the  vapour recovery 
system vacuum pump will start after pressing the <8> button. The setting is made by 
pressing the <E> key by entering the test time in <SSS> format and confirming with the 
<E> key.  
Parameter 
Meaning 
P11 = 5, 6...300  
Dry Test duration in seconds 
 
 
 
 
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
Error message in case of 
Factory setting 
60 seconds 
118
Sn      1
800101 
P10‐1 
 
detected mismatch 
 
E83‐1 
E83‐2 
E84‐1 
E84‐2 
E80‐1 
E80‐2 
E82‐1 
E82‐2 
E80‐1 
E80‐2 
E82‐1 
E82‐2 
E80‐1 
E80‐2 
E82‐1 
E82‐2 
E80‐1 
E80‐2 
E82‐1 
E82‐2 
E85 
E85 
E85 
E85 
 
M0 
 
60 
P11 