4.1.13. SERIAL NUMBERS OF THE PERIPHERAL UNITS (P10)
The parameter is used to display the serial numbers of the connected peripheral units. The actual serial
numbers of the peripheral units are compared with the numbers stored in the
processor unit memory. If a mismatch is detected, an error message is displayed
and fuel delivery is not allowed. The list of periphearal units is below.
Example: Parameter P10‐1, serial number of the main processor unit SN: 18‐00101 (see picture)
Parameter
Peripheral unit
P10‐1
Main processor unit
P10‐2
Main temperature sensors unit PDEINP1 (for temp. sensors 1 to 4)
P10‐3
Auxiliar temperature sensors unit PDEINP2 (for temp. sensors 5 to 8)
P10‐4
Mass meter A
P10‐5
Mass meter B
P10‐6
Main displaying unit (Master) of filling point A
P10‐7
Auxiliar displaying unit (Slave) of filling point A
P10‐8
Main electromechanical totalizers unit (Master) of filling point A
P10‐9
Auxiliar electromechanical totalizers unit (Slave) of filling point A
P10‐10
Main displaying unit (Master) of filling point B
P10‐11
Auxiliar displaying unit (Slave) of filling point B
P10‐12
Main electromechanical totalizers unit (Master) of filling point B
P10‐13
Auxiliar electromechanical totalizers unit (Slave) of filling point B
P10‐14
Main displaying unit (Master) of filling point C
P10‐15
Auxiliar displaying unit (Slave) of filling point C
P10‐16
Main electromechanical totalizers unit (Master) of filling point C
P10‐17
Auxiliar electromechanical totalizers unit (Slave) of filling point C
P10‐18
Main displaying unit (Master) of filling point D
P10‐19
Auxiliar displaying unit (Slave) of filling point D
P10‐20
Main electromechanical totalizers unit (Master) of filling point D
P10‐21
Auxiliar electromechanical totalizers unit (Slave) of filling point D
P10‐22
Pressure sensors unit PDEDPS with address 1
P10‐23
Pressure sensors unit PDEDPS with address 2
P10‐24
Pressure sensors unit PDEDPS with address 3
P10‐25
Pressure sensors unit PDEDPS with address 4
4.1.14. VAPOUR RECOVERY USER TEST DURATION – DRY TEST (P11)
The parameter specifies the test duration in seconds for which the vapour recovery
system vacuum pump will start after pressing the <8> button. The setting is made by
pressing the <E> key by entering the test time in <SSS> format and confirming with the
<E> key.
Parameter
Meaning
P11 = 5, 6...300
Dry Test duration in seconds
TATSUNO EUROPE a.s., www.tatsuno‐europe.com
Error message in case of
Factory setting
60 seconds
118
Sn 1
800101
P10‐1
detected mismatch
E83‐1
E83‐2
E84‐1
E84‐2
E80‐1
E80‐2
E82‐1
E82‐2
E80‐1
E80‐2
E82‐1
E82‐2
E80‐1
E80‐2
E82‐1
E82‐2
E80‐1
E80‐2
E82‐1
E82‐2
E85
E85
E85
E85
M0
60