Non-Resettable Volume Totalizers (P00); Daily Quantity Totalizers (P01); Daily Amount Totalizers (P02) - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

Fuel Dispensers TATSUNO EUROPE ‐ Installation and User Manual  ,  revision 10, January 2022 
4.1.5. NON‐RESETTABLE VOLUME TOTALIZERS (P00) 
Non‐resettable  electronic  totalizers  for  all  dispensing  hoses  (nozzles)  are  saved  in  the  memory  of  the 
electronic counter. These totalizers state what total volume was delivered by individual delivery hoses. 
These totalizers cannot be modified in any way. 
Parameter 
Meaning 
P00‐1 
quantity of the fuel delivered by hose 1 in centilitres (x 0.01L) 
P00‐2 
quantity of the fuel delivered by hose 2 in centilitres (x 0.01L) 
... 
... 
P00‐10 
quantity of the fuel delivered by hose 10 in centilitres (x 0.01L) 
 
NOTE
Number of totalizers of delivery hoses shown in the P00 parameter is conditioned by the configuration of 
 
the dispenser. The identification system of delivery hoses and products is described in Figure 77.
 
4.1.6. DAILY QUANTITY TOTALIZERS (P01) 
Electronic daily quantity totalizers for all dispensing hoses are stored in the electronic counter's memory. 
They indicate how much fuel has been delivered by the individual dispensing hoses after the last reset 
(e.g., after the start of the shift). These totalizers can be reset at any time using parameter P15 (see 
description below). 
Parameter 
Meaning 
P01‐1 
quantity of the fuel delivered by hose 1 in centilitres (x 0.01L) 
P01‐2 
quantity of the fuel delivered by hose 2 in centilitres (x 0.01L) 
... 
... 
P01‐10 
quantity of the fuel delivered by hose 10 in centilitres (x 0.01L) 
 
NOTE
Number of totalizers of delivery hoses shown in the P01 parameter is conditioned by the configuration of 
 
the dispenser. The identification system of delivery hoses and products is described in Figure 77.
 
4.1.7. DAILY AMOUNT TOTALIZERS (P02) 
Electronic daily amount totalizers for all dispensing hoses are stored in the electronic counter's memory. 
They indicate total amount of the fuel that has been delivered by the individual dispensing hoses after the 
last reset (e.g., after the start of the shift). These totalizers can be reset at any time using parameter P15 
(see description below). 
Parameter 
Meaning 
P01‐1 
amount of the fuel delivered by hose 1 in centilitres (x 0.01L) 
P01‐2 
amount of the fuel delivered by hose 2 in centilitres (x 0.01L) 
... 
... 
P01‐10 
Amount of the fuel delivered by hose 10 in centilitres (x 0.01L) 
 
NOTE
Number of totalizers of delivery hoses shown in the P01 parameter is conditioned by the configuration of 
 
the dispenser. The identification system of delivery hoses and products is described in Figure 77.
 
 
 
115
 
 
 
 