Daily Totalizers Reset (P15); Error Message Codes History (P20); Error Message Code Statistics Of Filling Point (P21, P22, P23, P24) - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

4.1.18. DAILY TOTALIZERS RESET (P15) 
The parameter is used to reset all daily totalizers of dispensing hoses. After setting the 
parameter value to <1> and confirming (<E> + <1> + <E>), all totalizers that are part of 
parameters P01 and P02 will be reset to 0. The message "done" appears and the parameter 
value goes to 0. 
Parameter 
Meaning 
P15=0 
Idle status 
P15=1 
Daily totalizers P01 and P02 reset to 0 
4.1.19. ERROR MESSAGE CODES HISTORY (P20) 
 The function is used to display the history of the last 100 error message codes that have occurred and displayed 
on the dispenser. The table of error messages codes is given in chapter 6.2.1. After switching to parameter P20, 
the display shows the code of the last error message and the designation for the filling point where the error 
occurred A, B, C or D (e.g., E41‐01 pulse generator connection error at input PUL1 for filling point A). After 
pressing the <E> key, the date and time of the fault will be displayed. After pressing the <+> key, the code of the 
penultimate error message code, etc. appears on the display.  
Parameter 
Meaning 
(P)20‐00 
code of the last error 
(P)20‐01 
code of the penultimate error 
... 
... 
(P)20‐98 
99th error code in the sequence 
(P)20‐99 
100th error code in the sequence 
 
NOTE
If two identical error message code occur in a row, then only the last one is displayed.
    
4.1.20. ERROR MESSAGE CODE STATISTICS OF FILLING POINT (P21, P22, P23, P24) 
 The parameter is used to display the cumulative numbers of individual error messages for a given filling point. 
The first line of the display shows the error message code and the second line the frequency of the error. After 
switching  to  parameter  P21  (error  message  code  statistics  for  filling  point  A),  the  display  shows  the  fault 
frequency for error message code E0. After pressing the <+> key, the frequency of the error message code E1... 
etc... appears on the display. The table of error message codes is given in chapter 6.2.1. 
Parameter 
Meaning 
P21 
Error message code statistics of filling point A 
P22 
Error message code statistics of filling point B 
P23 
Error message code statistics of filling point C 
P24 
Error message code statistics of filling point D 
 
NOTE
A  filling  point  (dispensing  site,  dispensing  point)  is  defined  as  a  place  where  one  independent  fuel 
 
dispensing (one pumping) can be performed. By default, a double‐sided dispenser has two filling points ‐ A and B 
(see  Figure  79),  a  single‐sided  dispenser  has  one  filling  point  ‐  A.  However,  there  are  variants  of  dispensers, 
especially combined dispensers, where two simultaneous pumping can be performed on one side of the dispenser 
diesel + AdBlue). The double‐sided dispenser then has four filling points A, B, C and D (see Figure 80) and the single‐
sided dispenser has two filling points A and B. Each filling point must have one main display and can serve one to 
five dispensing hoses.
 
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
Factory setting 
ENT 
A
E41‐01 
ENT 
20‐00
 
Err            0
 P21 
120
 
M0
 
 
230821
094706 
20‐00
 
 
Err            1
35 
 P21 
 P15 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shark economy seriesShark junior series

Table of Contents