Collective Signal Of The Dispenser Defect - "Collective Alarm" (Cng); Cable Characteristics - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

3.5.8. COLLECTIVE SIGNAL OF THE DISPENSER DEFECT – "COLLECTIVE ALARM" (CNG) 
For leading the collective signal of the CNG dispenser/module defect a 2‐wire H05VV5‐F 2X0.5 cable is 
used  (see  Table  24)  which  is  routed  from  the  main  switchboard  in  the  booth  to  the  communication 
distribution box of the dispenser. The H05VV5‐F 2x0.5 cable is routed from the distribution box to the 
counter case to relay contacts. Relay contacts shall close in each CNG dispenser defect and open after the 
defect is removed.  
Table 24 – Identification of wires in the line of a collective signal of the dispenser defect 
 
CAUTION
 
The max. load of the relay contacts for the dispenser defect indication is 250 V and 2 A. Always 
consult the dispenser manufacturer for the use of another control voltage and current. 
NOTE
 
In case of the CNG dispenser/module defect the delivery is interrupted and the display shows the defect 
code which corresponds to the defect type – e.g., broken hose, leak in the vehicle storage tank, meter failure, 
etc. At the same time, the relay of a collective dispenser defect is activated/switched on which informs the control 
centre of the fuel station about the dispenser defect. The relay automatically deactivates/switches off after the 
 
defect is removed. 
 
3.5.9. CABLE CHARACTERISTICS 
For  installations  it  is  necessary  to  use  cables  resistant  to  common  chemicals,  oils  and  with  sufficient 
thermal  and  mechanical  resistance.  These  conditions  are,  for  example,  met  by  harmonized  cables 
H05VV5‐F and H05VVC4V5‐K. The main characteristics of the cables are given in Table 25.  
Cable type 
H05VV5‐F 4x1.5 
H05VV5‐F 7x1.0 
H05VV5‐F 3x1.5 
H05VV5‐F 5x1.5 
H05VVC4V5‐K 5x0.5 
H05VV5‐F 2X0.5 
H05VV5‐F 5G1.5 
            Legend:  D
 ‐ cable outer diameter 
Anom
 
 
Identification of wires in the H05VV5‐F 2X0.5 cable 
identification 
ER 
ER 
Table 25 – Cable characteristics 
Function 
motor power supply 
pump switching  
counter  power  supply,  module  pump  switching, 
security line 
power supply for the counter with heating 
data line 
collective signal of the dispenser defect 
control of pressure section valves 
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
colour 
description 
black1 
ERR signal 
black2 
ERR signal 
 
108
Number of 
D
Anom
wires 
[mm] 
8.2 – 10.2 
9.5 – 11.8 
7.4 – 9.4 
9.1 – 11.4 
10.1 
5.9 
9.1 – 11.4 
 