4.4. TBELTX COUNTER 
The TBELTx electronic counter is set using the 4‐button keyboard or the preset keyboard if installed on 
the dispenser. Using the keyboard, you can: 
set unit prices of fuel products (in manual operation) 
read non‐resettable electronic litre totalizers of all delivery hoses 
change the dispenser working mode 
4.4.1. SETTING THE FUEL UNIT PRICE 
If the dispenser operates in the manual mode, then the product unit prices saved in the calculator memory 
where a single fuel unit price is assigned to each pump are used for calculation of the sum for dispensed fuel. 
Changes of the fuel price on the display will take effect after the next time the nozzle is taken out. A zero price 
value for all fuel products is set at the factory. It is necessary to set a non‐zero price, or dispensing will not 
commence and the error message E30 – "zero price" will appear.
the fuel unit prices sent from the control computer at each dispensing authorization is used to calculate the total 
dispensed sum. Prices saved in the parameter P03 are non‐functional.
How to set the fuel price in a manual mode 
The price change can only be made between powering on the counter and the first delivery on the dispenser. 
Turn the counter power supply off 
and on.  
Press  and  hold  the  button  2 
simultaneously  with  button  4  for  at 
least 3 seconds.  
The middle line shows the number of 
the set nozzle (product), the unit price 
is shown on the lower line. The price 
is  set  by  individual  locations.  The  set 
digit flashes. 
Use the button 1 to change the value 
of the flashing location.  
By button 2 you can move between different orders. 
Use the button 3 to change the number of the nozzle for which the price is being set. 
To quit the price setting, press the button 4. 
4.4.2. READING ELECTRONIC TOTALIZERS 
The  TBELTx counter is  equipped with electronic volume totalizers for each  delivery hose / nozzle.  The 
value  of  these  totalizers  can  be  determined  using  the  preset  keyboard  or  by  the  command  on  the 
communication line. Totalizer reset can be done using the P18 configuration parameter. Totalizer reset 
can only be done if the SW1‐1 switch is set to OFF. 
If the dispenser works in the automatic mode, 
 
 
Nozzle number
129
 
P r i c E 
 
   
   
        1
       
 
1 1 4 0
           
 
The set digit flashes 
 
€ 