In  order  to  install  the  data  line,  it  is  necessary  to  route  the  4‐wire  shielded  H05VVC4V5‐K  5x0.5 
communication cable (see Table 20) to each dispenser at the fuel station. The data cable must be routed 
radially  from  the  station  control  (booth,  control  panel)  to  the  first  module  of  each  dispenser  into  the 
communication  distribution  box.  From  the  communication  distribution  box,  the  data  line  is  led  to  the 
dispenser electronic head of the dispenser and connected to the counter.
 
NOTICE
 
For  the  communication  line,  we  recommend  using  a  5‐wire  shielded  communication  cable  with  a 
minimum  wire  cross‐section  of  0.5  mm
gasoline vapour. For this purpose, the manufacturer recommends using H05VVC4V5‐K harmonized cables. 
 
The TATSUNO EUROPE dispensers are standardly equipped with a PDE data line which is the RS485 line 
with  the  PDE  communication  protocol.  However,  it  is  possible  on  customer's  demand  to  add  a  data 
converter  to  the dispenser counter which will concert the PDE  data line to  a line of another type and 
communication protocol, e.g. PUMA LAN, ER4, IFSF‐LON, TATSUNO Party Line, etc. This also changes the 
meaning of wires in the data cable. Identification of wires for the most used types of data lines is described 
below, see Table 21. 
Identification of wires in the H05VVC4V5‐K 5x0.5 cable for different types of data lines 
wire colour 
PDE 
shield 
ST 
black 5 
reserve 
black 4 
reserve 
black 3 
reserve 
black 2 
black 1 
NOTE
 
For some type of data line a 2‐wire or 3‐wire cable would be sufficient ‐ see Table 21. Since the data line 
type may change during operation depending on the used control system, we recommend using a 5‐wire cable. 
 
3.5.5. SERVICE LINES 
Service  lines  serve  for  special  purposes.  These  lines  are  not  necessary  for  the  immediate  dispenser 
operation but they are also used in cases when it is necessary to remotely control some of the dispenser 
functions or lead some signals out of the dispenser. Always consult the engineers of TATSUNO EUROPE, 
Table 20 – Identification of wires in the data line 
Identification of wires in the H05VVC4V5‐K 5G0.5 cable 
identification 
colour 
SH 
shield 
‐ 
black5 
‐ 
black4 
‐ 
black3 
black2 
black1 
2
.  The  jacket  of  the  cable  must  be  self‐extinguishing  and  resistant  to 
Table 21 – Identification of wires for different types of data lines 
Easy Call 
PUMA LAN 
ST 
ST 
reserve 
unused 
reserve 
0V 
0V 
AM 
D(+) 
RX 
D(‐) 
TX 
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
description 
shield 
reserve 
reserve 
reserve 
data B 
data A 
PUMA LAN 
ER4 
+ probes 
ST 
ST 
LL1 
reserve 
LL0 
ZB 
GND 
YB 
RX 
ZA 
TX 
YA 
 
106
 
DART 
ST 
reserve 
reserve 
reserve 
 
ACTL 
ST 
reserve 
Rx‐ 
Rx+ 
Tx‐ 
Tx+ 
 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shark economy seriesShark junior series

Table of Contents