Vapour Recovery System History (P33, P34); Average Value Of Vapour/Fuel Ration (P35); Average Value Of Vapour Recovery Feedback Factor (P36) - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

4.1.26. VAPOUR RECOVERY SYSTEM HISTORY (P33, P34) 
The parameter is used to display the last 40 fillings on nozzles with activated vapour recovery for filling point A 
(P33) or B (P34). Records are only stored if the internal vapour recovery monitoring system is activated. After 
switching to parameter P33 (vapour recovery system history for filling point A), the display shows the vapour 
recovery values for the last delivery. The amount display line shows the percentage feedback factor value to 
one decimal place (see P36 for more information). The quantity display line shows the vapour / fuel ratio in 
percent with one decimal place. After pressing the <+> key, the penultimate filling appears. After pressing the 
<E> key, the date and time of the end of the saved delivery will appear on the display. 
Parameter 
Meaning 
(P)33 
Vapour recovery system history for filling point A 
(P)34 
Vapour recovery system history for filling point B 
 
 
Example: According to the last record (00), fuel delivery took place on 24.8.2021 at 12:51:01, during which the vapor recovery feedback 
factor was 98.0% and the ratio of the volume of extracted vapours to the volume of flowed fuel was 102.5% 
4.1.27. AVERAGE VALUE OF VAPOUR/FUEL RATION (P35) 
The parameter is used to display the average value of the ratio of the volume of extracted vapors to the volume 
of fuel dispensed. The average is calculated from the last 40 fillings for filling points A and B. After switching to 
parameter P35, the display shows the average volume ratio value for filling point A (P35‐A). The quantity display 
line shows the vapour/fuel ratio in percent with one decimal place. After pressing the <+> key, the average ratio 
value for filling point B (P35‐B) appears.  
Parameter 
Meaning 
P35‐A 
Average value of vapour/fuel ration for filling point A 
P35‐B 
Average value of vapour/fuel ration for filling point A 
Example: The average value of the ratio of the volume of extracted vapours to the volume of dispensed 
fuel for filling point A is 102.5% 
NOTE
The average value should be between 95% and 105%. If the value is lower than 95%, it probably means a 
 
problem with the vapor recovery vacuum pump or dirt in the VR piping. If the value is higher than 105%, then the 
regulation (VR solenoid valve) may not work properly. 
 
4.1.28. AVERAGE VALUE OF VAPOUR RECOVERY FEEDBACK FACTOR (P36) 
 The parameter is used to display the average feedback factor of the vapour recovery system. The average is 
calculated from the last 40 fillings for filling points A and B. After switching to parameter P36, the display shows 
the  average  value  of  the  feedback  factor  for  filling  point  A  (P36‐A).  On  the  quantity  display  line,  there  is  a 
percentage factor with one decimal place. After pressing the <+> key, the average factor value for filling point B 
(P36‐B) appears. 
Parameter 
Meaning 
P36‐A 
Average value of vapour recovery feedback factor for filling point A 
P36‐B 
Average value of vapour recovery feedback factor for filling point B 
Example: The average value of the vapour recovery feedback factor for filling point A is 98.0% 
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
980
1025 
33‐00
124
<E> 
240821
125101 
<E> 
33‐00
1025 
 P35‐A 
980 
 P36‐A 
 
 