4.1.22. MAINTENANCE HISTORY (P29) 
 The parameter allows you to display the identification codes of the last 50 service remote controllers that 
entered into service mode of the counter. After switching to parameter P29, the code of the last service remote 
controller (e.g., 19235) appears on the quantity display line. After pressing the <+> key, the penultimate remote 
controller code will appear. After pressing the <E> key, the date and time of entering the service controller into 
the setting mode of the dispenser counter will appear on the display (e.g., 24.8.2021 at 12:51:01). 
Parameter 
Meaning 
P(29)‐00 
Code of the last remote controller 
P(29)‐01 
Code of penultimate service controller 
... 
... 
P(29)‐49 
Code of the 50th service controller in the sequence 
 
NOTE
The yellow service remote controllers PDERT‐5S are used by authorized service personnel of 
 
TATSUNO  EUROPE  dispensers.  The  service  controllers  each  have  their  own  internal  identification 
code, which is written into the memory of the dispenser counter when entering the service mode. 
Using parameter P29, it is therefore possible to find out who entered the service mode of the counter 
and when, i.e., to identify the service technician and the time of the service intervention. 
4.1.23. CORRECTION FACTOR CHANGES HISTORY (P30) 
The  parameter  allows  you  to  display  the  last  50  records  of  changes  in  the  setting  of  correction  factors  of 
measuring  devices  (meters,  pulse  generators).  After  switching  to  parameter  P30,  the  last  record  of  the 
correction factor change appears on the display ‐ the original correction factor appears on the amount display 
line, the new changed correction factor appears on the quantity display line, the measuring device number (P01, 
P02, ... P10) appears on the unit price display line and flashes with the parameter number and the sequence 
number of the correction factor change record. After pressing the <+> key, the penultimate record of the change 
of the correction factor..., etc. appears. After pressing the <E> key, the date and time of the correction factor 
change will appear on the display.  
Parameter 
Meaning 
(P)30‐00 
Last record of the correction factor changes 
(P)30‐01 
Penultimate record of the correction factor changes 
... 
... 
P(30)‐49 
50th record of the correction factor changes 
 
Example: Last record (00) of the change of the correction factor of 
the measuring device P01, the original correction factor = 1,000, the 
new correction factor = 1,048, the date and time of the change of 
the correction factor = 24.8.2021 at 12:51:01)
NOTE 
The correction factor (of meter, pulse generator ...) is used in the metrological setting of the measuring 
device. Authorized service or legal metrology personnel will adjust it so that the measuring equipment complies 
with local regulations in terms of accuracy (MID guidelines, ....). The change of the correction factor is preceded by 
a removal of the metrological seal or sticker. After setting the factor, a new seal must be installed in the presence 
of a metrologist. Parameter P30 is used to check station owners and metrology officers. 
 
 
 
122
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
<E> 
INFO
19235 
<E> 
29‐00
 
1000
1048 
 
‚30‐00'
<E> 
1000
1048 
<E> 
30‐00
240821
125101 
29‐00
  
 
1000
1048 
‚P01'
240821
125101 
30‐00