3.4. MECHANICAL ATTACHMENT OF THE DISPENSER 
Dispensers are attached to special foundation frames by using anchor bolt supplied with the dispenser. 
The foundation frame of the dispenser is not a past of dispenser standard equipment but may be ordered 
separately. The foundation frame is concreted into the safety island, then the front and rear covers of the 
dispenser are removed, the dispenser is placed onto the foundation frame and attached by anchor bolts. 
CAUTION 
Where required by local regulations, for the sake of safety and environmental protection, a drip 
tray is installed under the dispenser. It prevents the leakage of fuel or technical liquid into soil due to possible 
leakage of the hydraulic system. The leaked liquid appears at a defined location outside the dispenser where 
the operator quickly identifies it and ensures a repair of the leakage of the hydraulic system.
Then the dispenser is connected to the suction pipeline with a bellows (suction piece) that is included in 
the  dispenser  delivery.  Appendix  1  shows  the  foundation  frames  and  foundation  plans  of  all  types  of 
dispensers  with  the  indicated  position  of  the  suction  pipeline  and  the  pipeline  for  extracting  gasoline 
vapour from dispensers. The vapour recovery pipeline is connected to the G 1'' lid of the pipeline. 
NOTE
 
The G 1" lid is included in the dispenser delivery. The suction line must be terminated by the G1" internal 
thread. 
 
CAUTION‐>LPG 
LPG extrusion from the dispenser and pipeline, e.g., while removing the dispenser, is carried 
out with nitrogen or inert gas. Extrusion by air or oxygen is prohibited!
 
NOTICE‐>LPG
According  to  EN  14678‐1:  2013,  clause  4.5.1.2,  the  liquid  phase  entry  into  the  LPG 
 
dispenser/module and the gas phase output from the LPG dispenser/module must be protected by a device (shear 
valve or break point) to ensure that the flow of liquid LPG or LPG vapour into atmosphere is prevented in case of 
pipeline rupture. The shear valve or break point must be firmly attached to the frame of the dispenser and to the 
ground.  Shear valves are not a part of the standard delivery of the dispenser! 
In  the  case  of  the  CNG  dispenser/module,  the  inlet  pipeline  of  the  outer  diameter  ø12  mm  (standard 
delivery) or ø16 mm (higher delivery /H) is inserted to the interconnecting threaded joint with a screw 
ring located under the ball shut‐off valve on the dispenser and then the threaded joint is tightened. The 
inlet  pipeline  must  be  fitted  with  shut‐off  valves  before  its  entrance  to  the  shaft  space  under  the 
dispenser for potential disassembly of the dispenser. 
CAUTION‐>CNG 
Joint design must ensure perfect tightness up to the pressure of 400 bar.
 
CAUTION‐>CNG 
The inlet pipeline of the dispenser must be secured by overpressure protection (overpressure 
valve, etc.) against pressure higher than the permissible maximum operating pressure.
 
 
 