Fuel Dispensers TATSUNO EUROPE ‐ Installation and User Manual  ,  revision 10, January 2022 
4.1.10. DISPLAYING THE PROGRAM VERSION AND CHECK SUMS (P05) 
This function shows the number of the program version of the dispenser counter and 
different  check  sums.  These  values  are  intended  for  metrology  authorities  and 
authorized service engineers. The meaning of the individual parameters is described in 
the table below. 
Parameter 
Meaning 
P05‐1 
Version of the metrologically relevant part of the program. It is specified in the type certificate (e.g., 102 = version V1.02) 
P05‐2 
CRC (check sum) of metrologically relevant part of the program. It is specified in the type certificate (e.g., dbd2 FFA4) 
P05‐3 
Version and release of the whole program (e.g., 1.02 release 14) 
P05‐4 
CRC (check sum) of the whole program (e.g., 27E6 622d) 
P05‐5 
CRC (check sum) of the temperature sensors unit PDEINP1 program (for temp. sensors 1 to 4). If not present „ ‐ ‐ ‐ ‐ " is displayed 
P05‐6 
CRC (check sum) of the temperature sensors unit PDEINP1 program (for temp. sensors 5 to 8). If not present „ ‐ ‐ ‐ ‐ " is displayed 
P05‐7 
Date and time the program compilation. The first line shows the time (hhmmss) and the second the date (DDMMYY). 
P05‐8 
CRC of the program of the pressure sensors unit PDEDPS with address 1. If not present, "‐ ‐ ‐ ‐" is displayed 
P05‐9 
CRC of the program of the pressure sensors unit PDEDPS with address 2. If not present, "‐ ‐ ‐ ‐" is displayed 
P05‐10 
CRC of the program of the pressure sensors unit PDEDPS with address 3. If not present, "‐ ‐ ‐ ‐" is displayed 
P05‐11 
CRC of the program of the pressure sensors unit PDEDPS with address 4. If not present, "‐ ‐ ‐ ‐" is displayed 
 
NOTE
Metrologically relevant data P05‐1 and P05‐2 also appear on the display for a while after the power on.  
 
 
NOTE
The calculated CRC (cyclic redundancy sum) values from sub‐parameters 1 and 3 are checked after switching 
 
on. If the calculated checksum is different from the stored correct sum, the dispenser is blocked and error message 
E13 is displayed. Higher cyclic checksum orders are displayed on the amount line, lower orders on the quantity line. 
The  CRC  of  the  peripheral  unit  programs  (PDEINP  and  PDEDPS)  is  checked  before  each  delivery  is  enabled.  If  the 
calculated value of the peripheral unit checksum does not match the correct value, delivery (fuelling, pumping) is not 
started and the corresponding error message is displayed.  
4.1.11. MODBUS INTERFACE ACTIVATION (P06) 
 The  modbus  interface  (diagnostic  data  line)  allows  service  organizations  to  remotely  diagnose  dispensers. 
Parameter P06 allows to activate the Modbus interface by entering a valid key (eight‐digit 
code). 
Parameter 
Meaning 
P06=0 
The Modbus license is not valid. Modbus interface is not active 
P06=1 
The Modbus license is valid. Modbus interface is active 
4.1.12. MANAGER MODE ACCESS PASSWORD (P08) 
 This function allows to view and change the password to the manager mode. The setting is made by pressing 
the <E> key by entering a new password in <PPPP> format and confirming <E>.  
Parameter 
Meaning 
P08 = 1 to 9999 
Manager mode access password 
 
 
 
 
Factory setting 
Factory setting 
117
INFO
 
M0 
 
M0 
1111 
1111 
 
 
102 
P05‐1 
P06 
P08 