Cng Delivery To Motor Vehicles - tatsuno OCEAN TOWER Series Installation And User Manual

Table of Contents

Advertisement

Fuel Dispensers TATSUNO EUROPE ‐ Installation and User Manual  ,  revision 10, January 2022 
5.3.3. CNG DELIVERY TO MOTOR VEHICLES 
Delivery start 
Before  the  delivery  starts,  the  dispenser  attendant  checks  whether  the  storage  tank  in  a  vehicle  has  a 
homologation mark, the vehicle engine and all electrical devices are turned off. Then he/she visually inspects 
the condition or wear of the filling neck/connector that could be the reason for leaks. If he/she finds serious 
deficiencies, he/she is entitled to refuse storage tank filling. In case of gas leak or danger the attendant shall 
finish the delivery. 
The  operation  of  the  dispenser  itself  is  ensured  by  the 
employee of the fuel station who lifts the delivery nozzle from 
the dispenser and connects it to the storage tank of the vehicle 
which must be secured against moving. Immediately after the 
nozzle  is  lifted  the  display  test  is  performed  –  displaying  all 
segments – and then it is reset and the product unit price is 
displayed. 
 After pressing the START button located on the counter case the electromagnetic valve opens at the inlet of the 
first  pressure  section  and  the  pressure  storage  tank  of  the 
vehicle is filled with compressed natural gas. In the moment 
when the delivery speed decreases under the defined limit, the 
electronic  counter  automatically  switches  delivery  to  the 
second  section  and  then  potentially  to  the  third  pressure 
section  –  depending  on  the  dispenser  and  fuel  station 
configuration.  
NOTE
Some dispensers, especially non‐public ‐ company dispensers, are not fitted with the sensors of 
   
delivery nozzle lifting. At such dispensers, the display test is performed after pressing the START button.
 
Delivery termination 
The delivery may be terminated for various causes. Possible causes of delivery termination and corresponding 
messages shown on the display are mentioned in table below 
Table 34 ‐ Causes for delivery termination 
1. Pressing the STOP button by the customer/attendant during the delivery 
2. Attaining the pre‐set sum, quantity, or limit values of the dispenser 
3. STOP command received from the superior system (payment terminal) 
4. Gas flow rate drop under the value set on the dispenser (e.g., < 2kg/min) 
5. Attaining the maximum possible mass calculated by temperature compensation 
6. Detection of an error event. 