6.1.4. CALIBRATION OF THE PETROL DISPENSERS WITH ULTRA HIGH FLOW (/UH) 
Very  high‐performance  fuel  dispensers  (above  120  L/min;  marked  /UH)  include  two  pumps  and  two 
meters ‐ the main pump & meter and the auxiliary pump & meter. Calibration of the meters is performed 
in the same way as in chapter 6.1.3, only the following procedure must be used: 
a) disconnect the auxiliary pump 
b) calibrate the main meter as described in 6.1.3 
c) connect the auxiliary pump 
d) calibrate the auxiliary meter settings as described in 6.1.3 
NOTE
 The auxiliary pump can be disconnected and connected either directly in the dispenser's electronic 
cabinet by disconnecting the auxiliary pump motor contactor or by setting a parameter, eg PDEX: P84 = 0 
(OFF) / 2 (ON). PDEX5: M8 / P11 = 0 (OFF) / 1.2... (ON). 
 
NOTE
 In the case of automatic electronic calibration of the meter (PDEX5 counter), it is not necessary to 
mechanically disconnect the pumps. When setting parameter M6‐P15 = 1 and M6‐P15 = 2, only one pump 
(main / auxiliary) is always switched on. 
 
 
 