How to read the electronic totalizers: 
You can only display the value of the totalizers on the counter display if all the nozzles are hung 
and the previous delivery is paid. 
Press and hold the buttons 3 and 4 simultaneously for at least 3 seconds. 
The  nozzle  number  appears  on  the  bottom 
line. The upper and middle lines display the 
totalizer value (the upper line shows higher 
orders). 
Use  the  1(+)  and  2(‐)  buttons  to 
change the nozzle number. 
To  end  the  display  of  the  totalizer, 
press the button 4 (Cancel). 
 
4.4.3. CHANGE OF THE WORKING MODE 
Changing the dispenser working mode must be performed when the dispenser is disconnected from the 
control  system  (e.g.  in  the  event  of  a  malfunction  of  the  control  system)  when  the  dispenser  is  to  be 
operated manually or vice versa when the dispenser is in a manual mode and must be connected to the 
control system.  
How to change the working mode:
Turn the power supply of the dispenser 
counter off and on. 
During 
the 
counter 
countdown),  press  and  hold  buttons  1 
and 4 simultaneously until the letter "P" 
flashes on the lower line indicating the 
entry to the setting mode. 
When  the  counter  test  is  completed, 
the parameter number P00 appears on 
the bottom line. 
The value of that parameter is displayed on the middle line. 
Opening the parameter for editing is made by pressing the button 3 (Enter). 
When the parameter is opened, its value flashes. 
Change the parameter value with buttons 1 and 2 to 0 – for automatic mode or 1 – for manual mode. 
To store the parameter value, press the button 3 (Enter). 
The parameter setting mode is ended by pressing the button 4 for at least 2 seconds (Cancel). 
 
 
test 
(zero 
 
130
TATSUNO EUROPE a.s., www.tatsuno‐europe.com 
1
    13
 
2
4438.56
3
    tot    1 
4
number
Nozzle 
1
S E T U P 
 
2
3
4
parameter no. 
totalizer value 
134438.56 l 
€ 
€/L 
 
parameter value 
€ 
P 00 